Building Filters
2009 WESTPORT 130'
- Fabricante: WESTPORT
Length: 130' | Beam: 26' | Max speed: 24 Knots | Cruising speed: 20 Knots | Cabins: 5 | Gross tonnage: 0.00 | Engine room: The Engine Room sound package consists of reflective barriers and absorptive insulation i...
$16,900,000 USDFort Lauderdale, FloridaPortables 9030M
- Fabricante: Jenco Instruments
Do range: 0.00 to 20.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±1.5% of reading or ±0.15 mg/L, whichever is greater | Do% saturation range: 0.0 to 200.0 % | Do% saturation resolution: 0.1% | Do% saturatio...
San Diego, CaliforniaASDevices KA8000plus
- Fabricante: ASDevices
Thetford Mines, CanadáPortables 9010M
- Fabricante: Jenco Instruments
Do range (ppm): 0.00 to 20.00 ppm | Do resolution (ppm): 0.01 ppm | Do accuracy (ppm): ±0.5% F.S. | Do% saturation range: 0.0 to 200.0% | Do% saturation resolution: 0.1% | Do% saturation accuracy: ±0.5% F.S. | Te...
San Diego, CaliforniaPortables 3011M Cond/TDS/Salt/Temperature Basis Portable Meter
- Fabricante: Jenco Instruments
Conductivity range: 0.000 uS/cm to 400.0 mS/cm | Conductivity resolution: 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm | Conductivity accuracy: ±0.5% F.S. | Tds range: 0.000 mg/L to 400.0 g/...
San Diego, CaliforniaRoland V-02HD MKII Streaming Video Mixer
- Fabricante: Roland
Video processing: 4:4:4 (Y/Pb/Pr), 10-bit | Input 1--2: HDMI Type A x 2 | Program out: HDMI type A | Preview out: HDMI type A | 1920 x 1200/60 hz: Reduced blanking | Transition: CUT, MIX (DISSOLVE), WIPE (9 types...
$499 USDLondres, Reino UnidoPortables 9011M DO/Temperature Basis Portable Meter
- Fabricante: Jenco Instruments
Do range: 0.00 to 20.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±0.5% F.S. | Do% saturation range: 0.0 to 200.0% | Do% saturation resolution: 0.1% | Do% saturation accuracy: ±0.5% F.S. | Temperature range:...
San Diego, CaliforniaPortables 9031M DO/Temperature Basis Portable Meter
- Fabricante: Jenco Instruments
Do range: 0.00 to 20.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±1.5% of reading or ±0.15 mg/L, whichever is greater | Do% saturation range: 0.0 to 200.0% | Do% saturation resolution: 0.1% | Do% saturation...
San Diego, CaliforniaPortables 6011M/6011EU pH/ORP/Temperature Basis Portable Meter
- Fabricante: Jenco Instruments
Ph range: -2.00 to 16.00 pH | Ph resolution: 0.01 pH | Ph accuracy: ±0.01 pH | Mv range: -1999 to 1999 mV | Mv resolution: 1 mV | Mv accuracy: ±0.1% F.S. | Temperature range: -10.0 to 120.0 °C | Temperature resol...
San Diego, CaliforniaPortables 9011B DO/Temperature Bluetooth Portable Meter
- Fabricante: Jenco Instruments
Do range: 0.00 to 50.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ± 0.5%F.S(only meter), 0 to 20 mg/L, ± 2% of the reading or ±0.2 mg/L, whichever is greater, 20 to 50 mg/L, ± 6% of the reading | Do% saturat...
San Diego, CaliforniaPortables 6011M/6011EU pH/ORP/Temperature Basis Portable Meter
- Fabricante: Jenco Instruments
Ph range: -2.00 to 16.00 pH | Ph resolution: 0.01 pH | Ph accuracy: ±0.01 pH | Mv range: -1999 to 1999 mV | Mv resolution: 1 mV | Mv accuracy: ±0.1% F.S. | Temperature range: -10.0 to 120.0 °C | Temperature resol...
San Diego, CaliforniaPortables 9031B DO/Temperature Bluetooth Portable Meter
- Fabricante: Jenco Instruments
Do range: 0.00 to 20.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±1.5% of reading or ±0.15 mg/L, whichever is greater | Do% saturation range: 0.0 to 200.0% | Do% saturation resolution: 0.1% | Do% saturation...
San Diego, CaliforniaPortables 3011B Cond/TDS/Salt/Temperature Bluetooth Portable Meter
- Fabricante: Jenco Instruments
Conductivity range: 0.000 uS/cm to 400.0 mS/cm | Conductivity resolution: 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm | Conductivity accuracy: ±0.5% F.S. | Tds range: 0.000 mg/L to 400.0 g/...
San Diego, CaliforniaPortables 6011B/6011BEU pH/ORP/Temp Bluetooth Portable Meter
- Fabricante: Jenco Instruments
Ph range: -2.00 to 20.00 pH | Ph resolution: 0.01 pH | Ph accuracy: ±0.01 pH | Mv range: -2000 to 2000 mV | Mv resolution: 1 mV | Mv accuracy: ±0.1% F.S. | Temperature range: -10.0 to 120.0 °C (14.0 to 248.0 °F) ...
San Diego, CaliforniaDissolved Oxygen Probe
Measurement technique: Luminescent Optical Technology | Accuracy do: ± 0.1 mg/L | Accuracy temperature: ± 0.2 °C | Response time: 40 second to 90% (T-90) | Body material: Stainless Steel 316 body | Sensor protect...
Kioto, Japón