Yamato DH1032
- Fabricante: Yamato
System: Forced air circulation and ventilation | Operating temp. range: Room temp. +15°C~300°C | Temperature fluctuation: 3.0°C (at 300°C) | Temperature slope: 18°C (at 300°C) | Temperature controller: PID contro...
Tokio, Japón
Yamato DKS200
- Fabricante: Yamato
Circulation type: Forced Convection | Operating temperature range: Room temp.+10 deg.C to 210 deg.C | Temp. control accuracy: ±1.0 deg.C (at 210 deg.C) | Temp. distribution accuracy: ±3.0 deg.C (at 210 deg.C) | M...
Tokio, Japón
Yamato CF820
- Fabricante: Yamato
Circulation type: Closed System Circulation By Pump | Operational ambient temperature: 5 deg.C to 35 deg.C | Operating temp. range: -20 deg.C to R.T. | Cooling capacity: Approx. 940W (810kcal/h) at Liquid temp. 1...
Tokio, Japón
Yamato WA711
- Fabricante: Yamato
Water purification method: Pretreatment -> Distillation -> Ion-exchange -> Filtration | Purified water / quality level: Distilled water / A1, Ion-exchanged water / A4 | Production of distilled water: Approx. 10 L...
Tokio, Japón
Yamato SK811
- Fabricante: Yamato
Circulation method: Forced convection | Temp. setting range: Room temp. +10~210°C | Temp. control accuracy: ±1℃(at 210℃)JTM K05 | Temp. fluctuation: 2℃(at 210℃)JIS | Temp. rising time: Approx. 60min. | Interior /...
Tokio, Japón
Yamato DKS300
- Fabricante: Yamato
Circulation type: Forced Convection | Operating temperature range: Room temp.+10 deg.C to 210 deg.C | Temp. control accuracy: ±1.0 deg.C (at 210 deg.C) | Temp. distribution accuracy: ±4.0 deg.C (at 210 deg.C) | M...
Tokio, Japón
Yamato DNF911
- Fabricante: Yamato
Method: Forced convection with manual exhaust damper | Heater: 1.65 kW×2 | Exhaust port: 50mm I.D. (Back) x 2pc. | Additional functions: Heater operation amount, Power failure recovery mode, User setting informat...
Tokio, Japón
Yamato DNF811
- Fabricante: Yamato
- Modelo: DNF811
Method: Forced convection with manual exhaust damper | Heater: 1.35 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode, User setting informatio...
Tokio, Japón
Yamato ADL311-A
- Fabricante: Yamato
Temp. adjusting unit setting range: 40 to 220deg.C (inlet temperature), 0 to 60deg.C (outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1deg.C | Drying air amount adjusting range: 0〜0.7m3/mi...
Tokio, Japón
Yamato DH612
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 360℃ | Temp. control accuracy (jtm k05): ±0.2℃(at 360℃) | Temp. fluctuation (jis): 2.0℃(at 360℃) | Temp. distribution accuracy...
Tokio, Japón
Yamato DH412
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 360℃ | Temp. control accuracy (jtm k05): ±0.2℃(at 360℃) | Temp. fluctuation (jis): 2.0℃(at 360℃) | Temp. distribution accuracy...
Tokio, Japón
Yamato GB210-A
- Fabricante: Yamato
Temp. adjusting range: 40 to 220°C (inlet temperature), 0 to 60°C (Outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1°C | Spraying system: Two-way nozzle, Nozzle No. 1A as standard | Drying...
Tokio, Japón
Yamato DXS200
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +10 deg.C to 210 deg.C | Temp. adjustment accuracy: ±1 deg.C (at 210 deg.C) | Temp. fluctuation: 6 deg.C (at 210 deg.C) | Temp. distribution accu...
Tokio, Japón
Yamato DF412
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 260℃ | Temp. control accuracy (jtm k05): ±0.1℃(at 260℃) | Temp. fluctuation (jis): 1.0℃(at 260℃) | Temp. distribution accuracy...
Tokio, Japón
Yamato GB210-B
- Fabricante: Yamato
Temp. adjusting range: 40 to 220°C (inlet temperature), 0 to °60(Outlet temperature) | Temperature adjusting accuracy: Inlet temperature ± 1°C | Spraying system: Two-way nozzle, Nozzle No. 1A as standard | Drying...
Tokio, Japón