Building Filters

Yamato SQ510
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temperature range: 45~135℃(45~80℃[pre heating temperature]/45~60℃[heat retention phase ]/65~100℃[disolution phase ]/105~135℃[sterilizing phase]) | M...
Tokio, Japón
Yamato SQ500
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temperature range: 45~135℃(45~80℃[pre heating temperature]/45~60℃[heat retention phase ]/65~100℃[disolution phase ]/105~135℃[sterilizing phase]) | M...
Tokio, Japón
Yamato SI601
- Fabricante: Yamato
Circulation method: Natural convection | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: 2°C (at 260°C) | Temp. distribution accuracy: 20°C (at 260°C) | Max. temp. reaching time: Approx. 7...
Tokio, Japón
Yamato SI402
- Fabricante: Yamato
Circulation method: Natural convection (for laboratory use only) | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: JTM K05 ±1°C (at 260°C) | Temp. distribution accuracy: JTM K05 ±6°C (at 2...
Tokio, Japón
Yamato IS801
- Fabricante: Yamato
Temperature range: Room Temp. +5~80℃ | Temp. adjustment accuracy: ±0.2℃ at 37℃ | Temp. distribution accuracy: ±1.0℃ at 37℃ | Time required to reach 60℃: Approx. 90 min. | Interior: Stainless Steel | Exterior: Col...
Tokio, Japón
Yamato IS601
- Fabricante: Yamato
Temperature range: Room Temp. +5~80℃ | Temp. adjustment accuracy: ±0.2℃ at 37℃ | Temp. distribution accuracy: ±1.0℃ at 37℃ | Time required to reach 60℃: Approx. 70 min. | Interior: Stainless Steel | Exterior: Col...
Tokio, Japón
Yamato IS401
- Fabricante: Yamato
Temperature range: Room Temp. +5~80℃ | Temp. adjustment accuracy: ±0.2℃ at 37℃ | Temp. distribution accuracy: ±1.0℃ at 37℃ | Time required to reach 60℃: Approx. 70 min. | Interior: Stainless Steel | Exterior: Col...
Tokio, Japón
Yamato ILE800
- Fabricante: Yamato
Circulation method: Natural convection by air jacket | Operating temperature range: 0 to +60℃ | Temp. control accuracy: ±0.2℃ (when refrigerator is in the continuous operation) ±0.3℃ (when refrigerator is in the ...
Tokio, Japón
Yamato IS901
- Fabricante: Yamato
Temperature range: Room Temp. +5~80℃ | Temp. adjustment accuracy: ±0.2℃ at 37℃ | Temp. distribution accuracy: ±1.0℃ at 37℃ | Time required to reach 60℃: Approx. 90 min. | Interior: Stainless Steel | Exterior: Col...
Tokio, Japón
Yamato IS602
- Fabricante: Yamato
Temperature range: Room Temp. +5~80℃ | Temp. adjustment accuracy: ±0.2℃ at 37℃ | Temp. distribution accuracy: ±1.0℃ at 37℃ | Time required to reach 60℃: Approx. 70 min. | Interior: Stainless Steel | Exterior: Chr...
Tokio, Japón
Yamato IS402
- Fabricante: Yamato
Temperature range: Room Temp. +5~80℃ | Temp. adjustment accuracy: JTM K05 ±0.2℃ at 37℃ | Temp. distribution accuracy: JTM K05 ±1.0℃ at 37℃ | Time required to reach 60℃: Approx. 70 min. | Interior: Stainless Steel...
Tokio, Japón
Yamato DP1030
- Fabricante: Yamato
Internal dimensions(w×d×h mm): 1000×1000×1000mm | External dimensions(w×d×h mm): 1300×1280×2110mm | Remarks(dimensions): 1000L | Power source: AC220V/380V Three-phase | Weight: 1000kg | Method: Vacuum drying by d...
Tokio, Japón
Yamato SI401
- Fabricante: Yamato
Circulation method: Natural convection | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: 2°C (at 260°C) | Temp. distribution accuracy: 20°C (at 260°C) | Max. temp. reaching time: Approx. 7...
Tokio, Japón
Yamato SM201 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~123℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.18MPa | Safety device: Self-diagnostic ...
Tokio, Japón
Yamato SN500
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temperature range: 45~135℃ 45~80℃(Preheating temperature)/45~60℃(Heat-retention process)/65~100℃(Solution process)/105~135℃(Sterilization) | Max. wo...
Tokio, Japón