Building Filters
HORIBA, Ltd. MESA-50
- Fabricante: Horiba
Target application: RoHS, ELV, Halogen Free | Meas. elements: 13Al - 92U | Sample type: Solid, Liquid, Powder | X-ray irradiation size: 1.2mm, 3mm, 7mm (Automatic switching) | X-ray primary filter: 4 types (Autom...
Kioto, JapónHORIBA Europe GmbH APMC-370
- Fabricante: Horiba
Principle of test gas production: via dilution | Accuracy: 0,1°C | Optional o3 generation: Internal O 3 via a UV tube in a thermostatically controlled enclosure Maximum concentration ±500ppb at 1l/min | Temperatu...
Kioto, JapónHORIBA, Ltd. MESA-50K
- Fabricante: Horiba
Target application: RoHS, ELV, Halogen Free | Meas. elements: 13Al - 92U | Sample type: Solid, Liquid, Powder | X-ray irradiation size: 1.2mm, 3mm, 7mm (Automatic switching) | X-ray primary filter: 4 types (Autom...
Kioto, JapónEL200
- Fabricante: Horiba
Inputs: pH/ORP 2 X 4-20 mA input, 2-wire or 4-wire (15v DC galvanically isolated source, 50mA maxi) | Outputs: 2 x 4-20mA active output (load of 500 ohm maxi) | Relays: 4x electromechanical SPDT (form C) contact,...
Kioto, JapónSpex Sample Prep Geno Grinder 2010
- Fabricante: Spex
Voltage: 15V/60Hz or 230V/50Hz | Ce approved: YES | Dimensions: 15.00 in (38.1 cm) wide x 20.49 in. (52 cm) deep x 25.25 in.(64.1 cm) high | Net weight (lbs): 87 lbs (39.5kg) | Gross weight (lbs): 115 lbs (52.2kg...
Kioto, JapónSpex Sample Prep Shaqer 1500
- Fabricante: Spex
Voltage: 115V/60Hz or 230V/50Hz | Ce approved: YES | Dimensions: 21.5 in. (54.6 cm) high x 11.25 in. (28.6 cm) wide x 17.0 in. (43.2 cm)deep | Weight: 40 lbs. (22 kg) | Motor: 1/7 HP. Maximum speed 1516 rpm | Pow...
Kioto, JapónSpex Sample Prep Disc Grinder 8530
- Fabricante: Spex
Voltage: 115V/60Hz or 230V/50Hz | Ce approved: YES | Dimensions: 19 in (48cm) x 19 in (48cm) x 40 in (102cm) | Net weight (lbs): 225 lbs (102kg) | Gross weight (lbs): 247 lbs (112kg), Palette 264 lbs (119.7kg) | ...
Kioto, JapónAC AUTOMATIC INSULATION/WITHSTANDING HiTESTER 3174
Testing voltage: 500 V DC, 1000 V DC | Voltage setting: Digital setting, Setting resolution: 0.01 kV | Waveform/frequency: Sine wave (Distortion ratio 5 % or less at no load), 50/60 Hz selectable | Current measur...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. Ca-11C
- Fabricante: Horiba
Measurement principle: Ion Selective Electrode | Minimum sample volume: 0.3 ml | Measurement range: 0.1~5.0 mmol/L | Resolution: 0.1 mmol/L | Accuracy: ±20% of reading value | Calibration points: 2 points (1.25 m...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUAtwin pH-33
- Fabricante: Horiba
Measurement principle: Glass Electrode | Minimum sample volume: 0.1ml (0.05ml with Sampling Sheet B) | Display: Custom (monochrome) digital LCD with backlight | Operating temperature: 5 to 40°C | Operating h...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUAtwin pH-11
- Fabricante: Horiba
Measurement principle: Glass Electrode | Minimum sample volume: 0.1ml (0.05ml with Sampling Sheet B) | Display: Custom (monochrome) digital LCD with backlight | Operating temperature: 5 to 40°C | Operating h...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUAtwin pH-22
- Fabricante: Horiba
Measurement principle: Glass Electrode | Minimum sample volume: 0.1ml (0.05ml with Sampling Sheet B) | Display: Custom (monochrome) digital LCD with backlight | Operating temperature: 5 to 40°C | Operating h...
Kioto, JapónHORIBA, Ltd. PA-1000
- Fabricante: Horiba
Detection method: Scintillation | Type of radiation measured: Gamma rays (γ) | Sensitivity: Min. 1000 counts per minute (1000 cpm) for 1 µSv/h | Relative error of indication: ±10% | Indicator value variation: Max...
Kioto, JapónHORIBA Scientific SLFA-20
- Fabricante: Horiba
Principle: X-ray fluorescent analysis | Sample: Sulfur content in petroleum products, such as heavy oil, naphtha, crude oil, etc. | Element: Sulfur | Range: 0-5% | Detection limit: 20 ppm | Accuracy: 15 ppm (with...
Kioto, JapónHORIBA Scientific VS70-PDA-HDR
- Fabricante: Horiba
Spectral coverage: UV-VIS (200–800 nm) with 477 l/mm grating, VIS (280--700 nm) with 582 l/mm grating, UV-NIR (200–985 nm) with double blazed 365 l/mm grating. On request, other spectral ranges available; differe...
Kioto, Japón