Building Filters
Spex Sample Prep Shaqer 1500
- Fabricante: Spex
Voltage: 115V/60Hz or 230V/50Hz | Ce approved: YES | Dimensions: 21.5 in. (54.6 cm) high x 11.25 in. (28.6 cm) wide x 17.0 in. (43.2 cm)deep | Weight: 40 lbs. (22 kg) | Motor: 1/7 HP. Maximum speed 1516 rpm | Pow...
Kioto, JapónSpex Sample Prep Disc Grinder 8530
- Fabricante: Spex
Voltage: 115V/60Hz or 230V/50Hz | Ce approved: YES | Dimensions: 19 in (48cm) x 19 in (48cm) x 40 in (102cm) | Net weight (lbs): 225 lbs (102kg) | Gross weight (lbs): 247 lbs (112kg), Palette 264 lbs (119.7kg) | ...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. Ca-11C
- Fabricante: Horiba
Measurement principle: Ion Selective Electrode | Minimum sample volume: 0.3 ml | Measurement range: 0.1~5.0 mmol/L | Resolution: 0.1 mmol/L | Accuracy: ±20% of reading value | Calibration points: 2 points (1.25 m...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUAtwin pH-33
- Fabricante: Horiba
Measurement principle: Glass Electrode | Minimum sample volume: 0.1ml (0.05ml with Sampling Sheet B) | Display: Custom (monochrome) digital LCD with backlight | Operating temperature: 5 to 40°C | Operating h...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUAtwin pH-11
- Fabricante: Horiba
Measurement principle: Glass Electrode | Minimum sample volume: 0.1ml (0.05ml with Sampling Sheet B) | Display: Custom (monochrome) digital LCD with backlight | Operating temperature: 5 to 40°C | Operating h...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUAtwin pH-22
- Fabricante: Horiba
Measurement principle: Glass Electrode | Minimum sample volume: 0.1ml (0.05ml with Sampling Sheet B) | Display: Custom (monochrome) digital LCD with backlight | Operating temperature: 5 to 40°C | Operating h...
Kioto, JapónHORIBA, Ltd. PA-1000
- Fabricante: Horiba
Detection method: Scintillation | Type of radiation measured: Gamma rays (γ) | Sensitivity: Min. 1000 counts per minute (1000 cpm) for 1 µSv/h | Relative error of indication: ±10% | Indicator value variation: Max...
Kioto, JapónHORIBA Scientific SLFA-20
- Fabricante: Horiba
Principle: X-ray fluorescent analysis | Sample: Sulfur content in petroleum products, such as heavy oil, naphtha, crude oil, etc. | Element: Sulfur | Range: 0-5% | Detection limit: 20 ppm | Accuracy: 15 ppm (with...
Kioto, JapónHORIBA Scientific VS70-PDA-HDR
- Fabricante: Horiba
Spectral coverage: UV-VIS (200–800 nm) with 477 l/mm grating, VIS (280--700 nm) with 582 l/mm grating, UV-NIR (200–985 nm) with double blazed 365 l/mm grating. On request, other spectral ranges available; differe...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. K-11
- Fabricante: Horiba
Measurement principle: Ion Selective Electrode | Minimum sample volume: 0.3ml (0.05ml with sampling sheet B) | Measurement range: 4 to 9900 ppm (mg/L) 0.1 to 250 mmol/L 2 to 5000 kg/10a | Resolution: 0 to 99...
Kioto, JapónHORIBA, Ltd. GI-700
- Fabricante: Horiba
Indicated error (linearity): ± 1.0 % of full-scale value for each component and range (Standard range ratio) ± 2.0 % of full-scale value for each component and range (Optinonal range ratio) | Zero drift: ± 1.0%/w...
Kioto, JapónHORIBA Scientific SLFA-2100/2800
- Fabricante: Horiba
Principle: X-ray fluorescent analysis | Sample: Sulfur content in petroleum products, such as heavy oil, naphtha, crude oil, etc. | Element: Sulfur | Range: 0 - 9,999% | Detection limit: 5 ppm or less | Accuracy:...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. Salt-22
- Fabricante: Horiba
Measurement principle: Ion Selective Electrode | Minimum sample volume: 0.3ml (0.05ml with sampling sheet B) | Salinity range: 0.01 to 25% by weight | Resolution: 0.00 to 0.99%: 0.01% 1.0 to 9.9%: 0.1% 10 to...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUAtwin NO3-11C/NO3-11S/NO3-11
- Fabricante: Horiba
Measurement principle: Ion Selective Electrode | Minimum sample volume: 0.3ml (0.05ml with sampling sheet B) | Nitrate (no3-) measurement range: 6 to 9900 ppm (mg/L) | Nitrate-nitrogen (no3-n) measurement ra...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. Na-11
- Fabricante: Horiba
Measurement principle: Ion Selective Electrode | Minimum sample volume: 0.3ml (0.05ml with sampling sheet B) | Measurement range: 2 to 9900 ppm (mg/L) 0.1 to 430 mmol/L | Resolution: 0 to 99 ppm: 1 ppm 100 t...
Kioto, Japón