 - TEMPERATURE LOGGER LR5011- Fabricante: HIOKI E.E
 - Measurement items: Temperature 1ch (with optional sensor) | Measurement range: -40.0°C to 180.0°C Depends on measurement range of sensor | Basic accuracy: ±0.5°C (main unit + sensor accuracy, at 0.0 to 35.0°C) N... Nagano, Japón
 - CLAMP LOGGER LR5051- Fabricante: HIOKI E.E
 - Measurement items: AC Current 2 channels (used with the optional current sensor; load current 2ch, leak current 2ch, or load/leak each 1ch) Caution: Current and leak current that occur intermittently cannot be me... Nagano, Japón
 - HUMIDITY LOGGER LR5001- Fabricante: HIOKI E.E
 - Measurement items: Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor) | Measurement range: Temperature: -40.0°C to 85.0°C, Humidity: 0 to 100% RH at sensor environment | Basic acc... Nagano, Japón
 - COMMUNICATION ADAPTER LR5091- Fabricante: HIOKI E.E
 - Function: • Settings: Communicates via infrared light with LR5000 series loggers to send and receive settings. • Graph function: Displays graphs of up to 16 channels, displays statistical data, etc. • Print funct... Nagano, Japón
 - MEMORY HiCORDER MR6000- Fabricante: HIOKI E.E
- Número de canales: 2 сhannels
 - Additional function: N/A | Number of input units: Max. 8 units | Number of channels: Max. 32 analog channels (when using the U8975), or 128 logic channels (when using the 8973) | Measurement ranges (20 div full-s... Nagano, Japón
 - PFS-ONE- Fabricante: HORIBA Europe GmbH
 - Hardware: standard desktop PC | Min. 8 gb memory: min. 16 GB memory | Software: application software for PFS-ONE Control Unit | Windows 10: Windows 10 or Windows 11 | Legislation compliance: ECE-R83, ECE-R49, EPA... Kioto, Japón
 - MEMORY HiCORDER MR8880- Fabricante: HIOKI E.E
 - Number of channels: 4 analog channels + 8 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND | Measurement ranges (10 div full-scale): 4 channels of voltage m... Nagano, Japón
 - MEMORY HiCORDER MR8875- Fabricante: HIOKI E.E
- Número de canales: 2 сhannels
 - Number of input units: Up to 4 slots | Number of channels: Max. 16 analog channels (Max. 60 channels when using the MR8902) + standard 8 logic channels + 2 pulse channels Note: For analog units, channels are iso... Nagano, Japón
 - MEMORY HiCORDER MR8740T- Fabricante: HIOKI E.E
 - Number of input units: Max. 27 slots | Number of channels: [Using the U8975] Max. 108 ch analog, or 96 ch analog + 48 ch logic (when used in combination with U8975 + 8973) [Using the 8966] Max. 54 ch analog, or 4... Nagano, Japón
 - MEMORY HiCORDER MR8870- Fabricante: HIOKI E.E
 - Number of channels: 2 analog channels + 4 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND | Measurement ranges: 10 mV to 50 V/div (10 div full-scale), 12... Nagano, Japón
 - MEMORY HiCORDER MR8740- Fabricante: HIOKI E.E
 - Max. number of channels: [Block I] 32 ch analog + 8 ch logic, or 29 ch analog + 56 ch logic (when used with built-in logic input + plug-in logic unit 8973 × 3) [Block II] 22 ch analog + 8 ch logic, or 19 ch anal... Nagano, Japón
 - MEMORY HiCORDER MR8741- Fabricante: HIOKI E.E
 - Max. number of channels: 16 ch analog + 16 ch logic, or 10 ch analog + 64 ch logic (when used with built-in logic input + plug-in logic unit 8973 × 3) | Number of slots: 8 slots (Max. 8) [Limitation on number of ... Nagano, Japón
 - RESISTANCE METER RM3548-50- Resistance range: 3 mΩ (3.5000 mΩ display Max., 0.1 µΩ resolution) to 3 MΩ range (3.5000 MΩ display Max., 100 Ω resolution), 10 steps Measurement accuracy: ±0.020 % rdg. ±0.007 % f.s. | Testing current: [at 3 mΩ ... Nagano, Japón
 - Syncerity VUV- Ccd ar coating: Without AR coating for 115 nm - 200 nm With AR coating for 135 nm - 1100 nm | Window: No window or with MgF2 window | Flange: Special flange for vacuum chamber with Viton 0-ring (Standard Syncerit... Kioto, Japón
 - LEAK CURRENT HiTESTER ST5541- Measurement methods: Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground. ... Nagano, Japón