Building Filters

Yamato IN604W
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, Japón
Yamato DVS603
- Fabricante: Yamato
Method: Natural gravity convection | Operating temp. range: Room temp.+5~260℃ | Temp. control accuracy: ±1℃(at 260℃) | Temp. distribution accuracy: ±5℃(at 260℃) | Max. temp. reaching time: Approx. 90 min. | Inter...
Tokio, Japón
Yamato DT300
- Fabricante: Yamato
Method: Forced air circulation | Operating temp. range: Room temp. +20°C to 300°C | Temp. control accuracy (jtm k05): ±0.3℃(at 100℃, 200℃, 300℃) | Temp. fluctuation (jis): 1.0°C (at 100 / 200°C) , 2.0°C (at 300°C...
Tokio, Japón
Yamato DT411
- Fabricante: Yamato
Temp. distribution accuracy: ±4.0°C (at 360°C) JTM K05 | Max. temp. reaching time: Approx. 80 min. (at 360°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, Japón
Yamato DE411
- Fabricante: Yamato
Temp. distribution accuracy: ±2.5°C (at 260°C) JTM K05 | Max. temp. reaching time: Approx. 70 min. (at 260°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, Japón
Yamato DT300H
- Fabricante: Yamato
Method: Forced air circulation | Operating temp. range: Room temp. +20°C to 300°C | Temp. control accuracy (jtm k05): ±0.3℃(at 100℃, 200℃, 300℃) | Temp. fluctuation (jis): 1.0°C (at 100 / 200°C) , 2.0°C (at 300°C...
Tokio, Japón
Yamato DT611
- Fabricante: Yamato
Temp. distribution accuracy: ±4.0°C (at 360°C) JTM K05 | Max. temp. reaching time: Approx. 80 min. (at 360°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, Japón
HORIBA, Ltd. Partica LA-960V2
- Fabricante: Horiba
Measurement principle: Mie scattering and Fraunhofer diffraction | Measurement range: 100 nm - 5000 μm | Measurement time: Typical measurement takes 2 seconds or longer. | Measurement method: Circulation measurem...
Kioto, Japón
Yamato DNF601
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.83 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mod...
Tokio, Japón
Yamato DNF301
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.8kW | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode, U...
Tokio, Japón
Yamato DNF411
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.6 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode...
Tokio, Japón
Yamato DNF611
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.83 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mod...
Tokio, Japón
Yamato DNF401
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.6 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode...
Tokio, Japón
MEMORY HiCORDER MR8870
- Fabricante: HIOKI E.E
Number of channels: 2 analog channels + 4 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND | Measurement ranges: 10 mV to 50 V/div (10 div full-scale), 12...
Nagano, Japón
Syncerity VUV
Ccd ar coating: Without AR coating for 115 nm - 200 nm With AR coating for 135 nm - 1100 nm | Window: No window or with MgF2 window | Flange: Special flange for vacuum chamber with Viton 0-ring (Standard Syncerit...
Kioto, Japón