Building Filters
Yamato BL401
- Fabricante: Yamato
Method: Pump circulating cooling | Operating temperature range: -15~+70°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity...
Tokio, JapónYamato HF200
- Fabricante: Yamato
Operating temp. range: Room temp. +5 to 200℃ | Temp. adjustment accuracy: ±0.2℃ (at 200℃ , at using φ16.5 testing tube) | Time to reach to max. temp.: Approx. 35min. (Room temp. 23℃ ) | Loadable block: Aluminium ...
Tokio, JapónYamato HF100
- Fabricante: Yamato
Operating temp. range: Room temp. +5 to 200℃ | Temp. adjustment accuracy: ±0.2℃ (at 200℃ , at using φ16.5 testing tube) | Time to reach to max. temp.: Approx. 30min. (Room temp. 23℃ ) | Loadable block: Aluminium ...
Tokio, JapónYamato BL810
- Fabricante: Yamato
Method: Pump circulating cooling | Operating temperature range: -15~+70°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity...
Tokio, JapónYamato ADL311-A
- Fabricante: Yamato
Temp. adjusting unit setting range: 40 to 220deg.C (inlet temperature), 0 to 60deg.C (outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1deg.C | Drying air amount adjusting range: 0〜0.7m3/mi...
Tokio, JapónYamato DKG810
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG650V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG650
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG810V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG610V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón