Building Filters

Yamato ADL311S-A
- Fabricante: Yamato
Temp. adjusting unit setting range: 40 to 220°C (inlet temperature), 0 to 60°C (Outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1°C | Drying air amount adjusting range: 0 to 0.7m3/min | Sp...
Tokio, Japón
Yamato GB210-A
- Fabricante: Yamato
Temp. adjusting range: 40 to 220°C (inlet temperature), 0 to 60°C (Outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1°C | Spraying system: Two-way nozzle, Nozzle No. 1A as standard | Drying...
Tokio, Japón
HORIBA, Ltd. IT-480 series
- Fabricante: Horiba
Spectral response: 8μm to 14μm | Measured temperature range: -50℃ to 500℃ | Output: USB (resolution = 0.1℃) Current (4 mA to 20 mA, resolution =0.24μA, non-insulated) | Currnent output range: -50℃ to 500℃ (factor...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HC-200NH
- Fabricante: Horiba
Combination sensor unit model: DO-2000 | Sensor model: 5700A: Sensor cap | Measurement range: Dissolved oxygen concentration: 0~20mg/L Display resolution 0.01mg/L Saturation degree: 0~200% Display res...
Kioto, Japón
Yamato BH302
- Fabricante: Yamato
Circulation type: Water Jet Pump Circulation (Closed System Circulation) | Operating temp. range: -20deg.C to 80deg.C | Temp. adjustment accuracy: ±0.02deg.C JTM K05 (at 20 deg.C) ±0.05deg.C JIS ( at 20 deg.C) | ...
Tokio, Japón
Yamato DH612S
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temp. range: RT+10°C to 360°C | Temp. gradient: 12℃(at 360℃) | Temperature control: PID control with a micro computer | Operation & control: Fixed temp., Auto...
Tokio, Japón
Yamato DH412S
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temp. range: RT+10°C to 360°C | Temp. gradient: 12℃(at 360℃) | Temperature control: PID control with a micro computer | Operation & control: Fixed temp., Auto...
Tokio, Japón
Yamato DF412S
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temp. range: RT+10°C to 260°C | Temp. gradient: 10℃(at 260℃) | Temperature control: PID control with a micro computer | Operation & control: Fixed temp., Auto...
Tokio, Japón
Yamato DF612S
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temp. range: RT+10°C to 260°C | Temp. gradient: 10℃(at 260℃) | Temperature control: PID control with a micro computer | Operation & control: Fixed temp., Auto...
Tokio, Japón
Yamato DH650
- Fabricante: Yamato
Method: Forced convection circulation | Operating temperature range: Room temp. +10~500°C | Temp. control accuracy: ±0.5℃(at 500℃) | Temp. distribution accuracy: ±3℃(at 300℃)、±5℃(at 500℃) | Max. temp. reaching ti...
Tokio, Japón
Yamato DIR631
- Fabricante: Yamato
Method: IR radiation+Forced convection circulation and ventilation | Operating temperature range: Room temp. +10 to 360°C | Temp. fluctation: 2.0°C (at 360°C, when IR Heater is OFF) | Temp. gradient: 12°C (at 360...
Tokio, Japón
HORIBA, Ltd. APHA-380
- Fabricante: Horiba
Component: Methane, non-methane hydrocarbons, total hydrocarbons (CH 4 , NMHC, THC) | Measuring principle: Flame lonization Detector Method (FID) with Selective Combustion | Measurement range: 0-5/10/20/50/100 pp...
Kioto, Japón
HORIBA, Ltd. APSA-380
- Fabricante: Horiba
Component: Sulfur dioxide (SO 2 ) | Measuring principle: Ultraviolet Fluorescence | Measurement range: 0-0.05/0.1/0.2/0.5/1.0/5.0/10/20 ppm (up to 8 ranges selectable, auto-range) *1 | Lower detection limit (2σ):...
Kioto, Japón
HORIBA, Ltd. APNA-380
- Fabricante: Horiba
Component: Nitrogen oxides (NO, NO 2 , NOx) | Measuring principle: Cross-Modulation Chemiluminescence | Measurement range: 0-0.1/0.2/0.5/1.0/2.0/5.0/10/20 ppm (up to 8 ranges selectable, auto-range) | Lower detec...
Kioto, Japón