Building Filters
HORIBA Advanced Techno Co., Ltd. HE-480H
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (4-electrode method) | Cell constant: 1.0/cm | Seawater salinity conversion value (%): 0.00 to 4.00 | Nacl salinity conversion valu...
Kioto, JapónFTX-ONE-CL
- Fabricante: HORIBA, Ltd.
Measurement target: Exhaust gas from internal combustion engine (Dilute measurement) | Target components*1: Max. 28 components | Target components sets*2: Standard set : Gasoline / Diesel vehicle CNG set | Princi...
Kioto, JapónHORIBA, Ltd. PX-375
- Fabricante: Horiba
Product name: Continuous Particulate Monitor with X-ray Fluorescence | Measured object: Particulate matter of black color | Measurement content: Particulate mass concentration and element concentration | Flow rat...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HP-480TP
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC, input/output isolated t...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HP-960FTP
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Repeatability: Within±0.05 pH (Equivalent input) | Linearity: ...
Kioto, JapónHORIBA Scientific Fluorolog-QM
- Fabricante: Horiba
Signal-to-noise ratio: (>35,000:1 FSD) | Data acquisition rate: 1,000,000 points/sec. to 1 point/1000 sec. | Inputs: 4 photon counting (TTL); 4 analog (+/- 10 volts); 1 analog reference channel (+/- 10 volts);...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HT-110
- Fabricante: Horiba
Product name: Total organic carbon analyzer (TOC analyzer) | Measurement method: Continuous UV oxidation conductivity method | Measurement limit: 0 ppb to 1000 ppb | Measurement range: 0 ppb to 100/500/1000 ppb |...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480R
- Fabricante: Horiba
Product name: industrial resistance meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃ | Repeatability: Wit...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480R
- Fabricante: Horiba
Product name: Industrial resistance meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01 / cm | Temperature sensor specifications: Platinum resistance 1000 Ω / 0 °C | Repeatabilit...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HD-480
- Fabricante: Horiba
Product name: Dissolved oxygen meter | Measurement method: Galvanic cell method | Measuring range: Dissolved oxygen 0 mg/L to 20 mg/L, 0.01 mg/L resolution Saturation 0% to 200%, 1% resolution Temperature 0℃ to 4...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480C
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm, 0.1/cm, or 1.0/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HP-480
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC: input/output isolated t...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HP-480PL
- Fabricante: Horiba
Product name: Pulse proportional control pH meter for industrial use | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA t...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480H
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (4-electrode method) | Cell constant: 1.0/cm | Seawater salinity conversion value (%): 0.00 to 4.00 | Nacl salinity conversion valu...
Kioto, Japón