Building Filters
AC CLAMP METER CM3281
Ac current range: 42.00 to 2000 A, 3 ranges (50 Hz to 60 Hz, Average rectified), Basic accuracy 50-60 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (...
Nagano, JapónHORIBA Scientific Fluorolog-QM
- Fabricante: Horiba
Signal-to-noise ratio: (>35,000:1 FSD) | Data acquisition rate: 1,000,000 points/sec. to 1 point/1000 sec. | Inputs: 4 photon counting (TTL); 4 analog (+/- 10 volts); 1 analog reference channel (+/- 10 volts);...
Kioto, JapónAC LEAKAGE CLAMP METER CM4002
Ac current range: 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Basic accuracy 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Basic accur...
Nagano, JapónYamato WGH201
- Fabricante: Yamato
Water quality of distilled water: Normal water: JIS K 0557 A4 After manual refreshing: ASTM D1193 Type1 | Water quality of deionized water: JIS K0557 A4 | Collection of of distilled water: Pretreatment Cartrid...
Tokio, JapónINSULATION TESTER IR4053
- Fabricante: HIOKI E.E
Rated output voltage: 50 V DC | Effective maximum indicated value: 100 MΩ | Measuring range/ accuracy: 0.200 to 500 MΩ / ±4% rdg. 501 to 2000 MΩ / ±8% rdg. | Other measuring range / accuracy: 0 to 0.199 MΩ / ±2%...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HT-110
- Fabricante: Horiba
Product name: Total organic carbon analyzer (TOC analyzer) | Measurement method: Continuous UV oxidation conductivity method | Measurement limit: 0 ppb to 1000 ppb | Measurement range: 0 ppb to 100/500/1000 ppb |...
Kioto, JapónAC CLAMP METER CM3291
Ac current range: 42.00 to 2000 A, 3 ranges (40 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (at 4.2 V ...
Nagano, JapónDIGITAL MULTIMETER DT4224
Dc voltage range: 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±1.0 % ...
Nagano, JapónLUX METER FT3424
Standards: DIN 5032-7: 1985 class B, JIS C 1609-1: 2006 general AA class | Light receiving element: Silicon photo diode | Range selection: Auto/ Manual | Linearity: ±2% rdg. (Multiply by 1.5 for display values i...
Nagano, JapónIMPEDANCE ANALYZER IM3570
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs,...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HE-480R
- Fabricante: Horiba
Product name: industrial resistance meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃ | Repeatability: Wit...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480R
- Fabricante: Horiba
Product name: Industrial resistance meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01 / cm | Temperature sensor specifications: Platinum resistance 1000 Ω / 0 °C | Repeatabilit...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...
Kioto, JapónIMPEDANCE ANALYZER IM7587
Measurement modes: LCR mode, Analyzer mode (sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, JapónIMPEDANCE ANALYZER IM7580A
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón