Building Filters
AC CLAMP METER CM4141-50
Ac current range: 60.00 A to 2000 A, 3 ranges (45 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (60 A range) | Crest factor: For the 60.00 A range: 2.5 (greater than 50.00 A and less than or...
Nagano, JapónINFRARED THERMOMETER FT3700, FT3701
Measurement temperature range: -60.0˚C to 550.0˚C (-76˚F to 1022˚F), 0.1˚C resolution | Accuracy: -35.0˚C to -0.1˚C (-31.0˚F to 31.9˚F) : ±10 %rdg. ±2˚C 0.0˚C to 100.0˚C (-32.0˚F to 212.0˚F) : ±2˚C 100.1˚C to 500...
Nagano, JapónPFS-ONE
- Fabricante: HORIBA Europe GmbH
Hardware: standard desktop PC | Min. 8 gb memory: min. 16 GB memory | Software: application software for PFS-ONE Control Unit | Windows 10: Windows 10 or Windows 11 | Legislation compliance: ECE-R83, ECE-R49, EPA...
Kioto, JapónYamato BH302
- Fabricante: Yamato
Circulation type: Water Jet Pump Circulation (Closed System Circulation) | Operating temp. range: -20deg.C to 80deg.C | Temp. adjustment accuracy: ±0.02deg.C JTM K05 (at 20 deg.C) ±0.05deg.C JIS ( at 20 deg.C) | ...
Tokio, JapónYamato DT411
- Fabricante: Yamato
Temp. distribution accuracy: ±4.0°C (at 360°C) JTM K05 | Max. temp. reaching time: Approx. 80 min. (at 360°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, JapónYamato DE411
- Fabricante: Yamato
Temp. distribution accuracy: ±2.5°C (at 260°C) JTM K05 | Max. temp. reaching time: Approx. 70 min. (at 260°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, JapónYamato DE611
- Fabricante: Yamato
Temp. distribution accuracy: ±2.5°C (at 260°C) JTM K05 | Max. temp. reaching time: Approx. 70 min. (at 260°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, JapónYamato DT611
- Fabricante: Yamato
Temp. distribution accuracy: ±4.0°C (at 360°C) JTM K05 | Max. temp. reaching time: Approx. 80 min. (at 360°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. HE-960HI
- Fabricante: Horiba
Product name: Conductivity meter | Measuring method: Four-electrode type | Cell constant: 0.1/cm | Temperature sensor specifications: Resistance thermometer bulb 1000 Ω/0℃ | Temperature: −30℃ to 160℃ | Naoh: 0% t...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. Finesse Solutions, LLC HE-960CW
- Fabricante: Horiba
Product name: Industrial 2-channel conductivity meter | Measurement method: Electrode type (2-electrode method) | Sensor input: 2 channels (for concurrent measurement with sensors isolated each other) | Cell cons...
Kioto, JapónHORIBA, Ltd. IT-480 series
- Fabricante: Horiba
Spectral response: 8μm to 14μm | Measured temperature range: -50℃ to 500℃ | Output: USB (resolution = 0.1℃) Current (4 mA to 20 mA, resolution =0.24μA, non-insulated) | Currnent output range: -50℃ to 500℃ (factor...
Kioto, JapónHORIBA, Ltd. SZ-100-Z2 and SZ-100-HZ2 (with zeta potential measurement unit)
- Fabricante: Horiba
Measurement principles: Particle size measurement: Dynamic Light Scattering Molecular weight measurement: Debye plot method (static scattered light intensity) | Measurement range: -500 to +500 mV | Maximum sample...
Kioto, JapónAC/DC HIGH VOLTAGE DIVIDER VT1005
Maximum rated voltage: 5000 V rms, ±7100 V peak (*1) | Maximum rated voltage (line-to-ground): No measurement category: 5000 V AC/DC (*2) Measurement category II: 2000 V AC/DC (*3) Measurement category III: 1500 ...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. 5800
- Fabricante: Horiba
Product name: Peracetic acid sensor ※3 | Temperature compensation element: Platinum resistance thermometer (Pt1000) 1000 W at 0℃, 3850 ppm/℃ | Measurement range: 100 to 4000ppm (0.010 to 0.400%) | Repeatability: ...
Kioto, JapónMEXA-1300R
- Fabricante: HORIBA, Ltd.
Compatible standards: CE, FCC (Class A) | Analyzing target: Exhaust gases of two-cycle and four-cycle engines | Measurement item and range: CO : 0.00% vol - 10.00% vol HC : 0ppm vol - 10,000ppm vol (N-hexane) CO...
Kioto, Japón