Building Filters
- Böckten, Suiza
UV500
Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 – 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0°C to 30...
Kioto, JapónUV300
Sample flow: Recommended: 0 - 5 l/min | Sample pressure: 0 - 4 Bar (0 - 1 Bar with sampling peristaltic pump) | Sample temperature: 0 - 80 °C | Wet parts material: Quartz, Polypropylene, Polyethylene, FPM (viton)...
Kioto, JapónUV500 IMO
Sample flow: Recommended : 0 – 5 L/min | Sample pressure: 0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump) | Sample temperature: 0 °C to 80 °C 0 to 80 °C for NH4 or H2S | Wet parts material: Quartz, Polypropy...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. F-11
- Fabricante: Horiba
Measurement principle: Ion selective electrode | Minimum sample volume: 0.3 ml (0.01 ml with sampling sheet B) | Measurement range: 0.1 to 990 ppm (mg/L) | Resolution: 0.1 to 9.9 ppm: 0.1 ppm 10 to 99 ppm: 1 ppm ...
Kioto, JapónFluke Networks DSX-5000 Cable Analyser Cat6a Ethernet Certifier Complete Kit Calibrated
- Fabricante: Fluke
- Modelo: DSX5000
Weight: 8 kg | Dimensions: 45 × 35 × 35 cm
$8,897 USDEpping, Australia- Kioto, Japón
Auto Positioning 23 Slots Automobile Automotive Car Motor Starter Armature Testing Machine WIND-ATS-02
- Fabricante: Wind Automation
Lugar de origen: Máquina china para producir motor eléctrico de arranque | Cantidad mínima de pedido: 1pc
Shanghái, China- $1,840 USDMitchell Park, Australia
- $3,388 USDMitchell Park, Australia
F-DGSi COSMOS N2.M Nitrogen Generator
- Fabricante: F-DGSi
Models: COSMOS.N2.M.3500 | N2 flow rate l/min: Up to 35 L/min | N2 purity: 95% – 99.5% * | Outlet pressure: Up to 8 bar (116 psi); user adjustable | Min/max air inlet pressure: 5.5 bar – 10 bar / 80 – 145 psi | M...
Évry, FranciaFor Parts HITACHI 912
- Fabricante: Hitachi
- Modelo: 912
Envío desde: Italia | Tipo de analizador: cerrado
$579 USDPortici, ItaliaCHEMICAL IMPEDANCE ANALYZER IM3590
Measurement modes: LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysi...
Nagano, JapónHORIBA, Ltd. 51 series
- Fabricante: Horiba
Measuring principle: Non-Dispersive Infrared Absorption Method (NDIR) | Component: CO, CO 2 , CH 4 , etc. *1 | Span ±0.5% of full scale: Span : ±1.0% of full scale | Linearity: ±1.0% of full scale | Optional ran...
Kioto, JapónQuestron Technologies Corp Vulcan by Questron
- Fabricante: Questron Technologies Corp
Syringe pump: 8 individually opereted syringes Teflon syringe to handle HF acid All Teflon values and fittings to provide inert environment Programmed to dispense precise amounts from 6 syringes at same time Desi...
Kioto, Japón