Yamato FP103
- Fabricante: Yamato
- Modelo: FP103
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato FP303
- Fabricante: Yamato
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato FP313
- Fabricante: Yamato
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato FP413
- Fabricante: Yamato
- Modelo: FP413
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKG610V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG810
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG650V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG650
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG810V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DT411
- Fabricante: Yamato
Temp. distribution accuracy: ±4.0°C (at 360°C) JTM K05 | Max. temp. reaching time: Approx. 80 min. (at 360°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, JapónYamato DNE650
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE670V
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE850V
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE850
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE670
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, Japón