6ES7626-2DG04-0AE3 SIMATIC C7-626/P DP, COMP. UNIT en Shenzhen, Guangdong, China

Especificaciones

Condición
nuevo
Artikelnummer
6ES7626-2DG04-0AE3
Password protection
Yes
Password levels
9
Semigraphic
Yes
Pixel graphics
Yes; Access to external editors
Number of process images
depending on user memory
Number of variables in message text, max.
8
Operating messages, max.
2 000; depending on user memory
Scroll operating messages, max.
512
Number of entries in operational log, max.
512; Entries in ring buffer
Fault messages
Yes
Number of fault message, max.
2 000; depending on user memory
Number of entries in fault message buffer, max.
512; Entries in ring buffer
Number of symbol/character sets
4
Number of recipes, max.
255
Data records per recipe, max.
500
Entries per data record, max.
500
Recipe data memory, max.
64 kbyte
Design of display
LC-Display, CCFL-backlit, passive mono; active display area 105 x 79 mm
Dynamic objects
Input, output, input/output fields, date/time fields, symbolic input/output fields, bar graphs, characteristics, pictorial presentation etc.
Horizontal image resolution
320
Vertical image resolution
240
Mtbf backlighting (at 20 °c)
20 000 h; about 2.2 years
Number of function keys
10
Number of softkeys
14
24 v dc
Yes
Permissible range, lower limit (dc)
20.4 V
Permissible range, upper limit (dc)
28.8 V
Rated value (dc)
24 V
Current consumption, typ.
700 mA
Current consumption, max.
2 A
Power loss, typ.
17 W
Integrated
1
Integrated feprom, max.
512 kbyte
Integrated ram, max.
260 kbyte
Present
Yes
With battery
Yes; all data
Without battery
Yes; 4736 Byte: parameterizable for memory bits, times, counters, data
For bit operations, typ.
0.3 µs
For bit operations, max.
0.6 µs
For word operations, typ.
1 µs
For fixed point arithmetic, typ.
2 µs
For floating point arithmetic, typ.
50 µs
For timer/counter operations, typ.
12 µs
Number, max.
256 byte
Number of free cycle obs
1; OB 1
Number of time alarm obs
1; OB 10
Number of time interrupt obs
1; OB 35
Number of process alarm obs
1; OB 40
Number of startup obs
1; OB 100
Number of asynchronous error obs
8; OB 80, 81, 82, 85, 86, 87, 121, 122
Per priority class
8
Number
1; UI3
Of which retentive with battery
0 to 2047
Can be set
Yes
Lower limit
1 ms
Upper limit
6 000 ms
Of which retentive without battery
0 to 2047
Counting range
0 to 16777215
Retentivity available
Yes
Inputs
128 byte
Outputs
128 byte
Number of modules per system, max.
8
Number of modules per dp slave interface, max.
32; 122 byte address space per DP station
Connectable programming devices/pcs
SIMATIC PG/PC, standard PC
Interface module im 360 integrated
Yes
Via cp
1; CP 342-5
Fm
8
Cp, point-to-point
4
Cp, lan
2
Number of expansion modules, max.
24
Analog inputs/outputs, max.
192
Digital inputs/outputs, max.
768
Modules per rack, max.
8
Rack, number of rows, max.
3
Hardware clock (real-time clock)
Yes
Number of digital inputs
16
Rated value, dc
24 V
For signal "0"
-3 to 5V
For signal "1"
typ. 11.5 mA
For signal "1", typ.
11.5 mA
At "0" to "1", max.
4.8 ms; typically 3 ms
Cable length, shielded, max.
200 m
Cable length unshielded, max.
600 m
Number of digital outputs
16
Short-circuit protection
Yes; Clocked electronically
Limitation of inductive shutdown voltage to
48 V
Lamp load, max.
5 W
For signal "1", min.
L (-0.8 V)
For signal "1" rated value
0.5 A
For signal "1" minimum load current
5 mA
For signal "0" residual current, max.
0.5 mA
With resistive load, max.
100 Hz
With inductive load, max.
0.5 Hz
Up to 20 °c, max.
4 A
Up to 40 °c, max.
2 A
Number of universal inputs
4
Usable as
UI1, UI2: Digital/alarm input 24 V DC or up/down counter; UI3: Digital/alarm input 24 V DC or up/down counter or frequency/period duration counter; UI4: Digital/alarm input 24 V DC
Counter frequency, max.
10 kHz
Number of analog inputs
4
Permissible input voltage for voltage input (destruction limit), max.
30 V
Permissible input current for current input (destruction limit), max.
30 mA
Cycle time (all channels), typ.
2 ms
Voltage
Yes
Current
Yes
10 v to 10 v
Yes
Input resistance (-10 v to 10 v)
50 kΩ
20 to 20 ma
Yes
Input resistance (-20 to 20 ma)
105.5 Ω
4 to 20 ma
Yes
Input resistance (4 to 20 ma)
105.5 Ω
Number of analog outputs
4
Voltage output, short-circuit protection
Yes
Voltage output, short-circuit current, max.
25 mA
Current output, no-load voltage, max.
16 V; /-
Cycle time (all channels) max.
4 ms; typ. 2 ms
10 to 10 v
Yes
With voltage outputs, min.
2 kΩ
With voltage outputs, capacitive load, max.
1 µF
With current outputs, max.
0.5 kΩ
With current outputs, inductive load, max.
1 mH
Resolution with overrange (bit including sign), max.
12 bit
Conversion time (per channel)
0.5 ms
For resistive load
0.1 ms
For capacitive load
3.3 ms
For inductive load
0.5 ms
2-wire sensor
Yes
Permissible quiescent current (2-wire sensor), max.
2 mA
Voltage, relative to input area, ( /-)
0.6 %
Current, relative to input area, ( /-)
0.6 %
Voltage, relative to output area, ( /-)
0.5 %
Current, relative to output area, ( /-)
0.6 %
Number of printer interfaces
1; RS 232
Cable length, max.
9 100 m; without repeaters 50 m; with 2 repeaters: 1100 m; with 10 repeaters in series: 9100 m; via fiber optic cable: 23.8 km (with star hubs or OLMs)
Dp slave
Yes
Number of nodes, max.
32; PG/PC, OP, C7, S7-300/400, M7
Transmission rate, max.
12 Mbit/s
Number of dp slaves, max.
64
User data per dp slave, max.
122 byte
Pg/op communication
Yes
Supported
Yes; occupies 2 nodes per device (1 x CPU, 1 x OP)
S7 extended communication
Yes; Server
Of which dynamic
8
Of which static
4
Substitute values connectable
Yes; Parameterizable
Alarm cycle
Yes; Parameterizable
Diagnostic alarm
Yes; parameterizable for parameter errors, measuring range exceeded, wire break detection at 4 to 20 mA via software
Diagnostic functions
Yes
Number of counter inputs
3; UE1, UE2, UE3
Principle
Counting of fixed time units between two positive edges
Counting range, description
UI1, UI2: up: 0 to 65535, down: 65535 to 0; UI3: up: 0 to 16777215, down: 16777215 to 0
Counting alarm backward counter
on reaching "0"
Counting alarm forward counter
on reaching limit value
Release
In the program
Limit value (setpoint) default
one counter per value
Number of frequency counters
1; UI3
Gate width, adjustable
Yes
Gate width
0.1 / 1 / 10 s (adjustable)
Cycle duration, max.
8.38 s; or 0.12 Hz
Counting range, lower limit
0
Counting range, upper limit
16 777 214
Galvanic isolation digital inputs
Yes
Between the channels, in groups of
8
Galvanic isolation digital outputs
Yes; Optocoupler
Galvanic isolation analog inputs
Yes; shared with AO
Galvanic isolation analog outputs
Yes; shared with AI
Galvanic isolation universal inputs
No
Isolation checked with
500 V DC
Interference emission acc. to en 55022, class a
Yes; Noise emission: Class A / EN 55022; conducted interference: IEC 1000-4-4, IEC 1000-4-5; noise immunity: IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4, IEC 1000-4-6, EN 50140
Ip20
Yes; Housing
Ip65
Yes; Front
Din/iso 9001
Yes; Certification of production and development
Csa approval
Yes; C22.2 Number 142
Ul approval
Yes; UL 508
Fm approval
Yes; FM-Standards No. 3611, 3600, 3810 Class I, Division 2, Group A, B, C, D
Developed in accordance with iec 61131
Yes; EN 61131-2 (IEC 1131-2)
45 degree installation, min.
0 °C
45 degree installation, max.
30 °C
Horizontal installation, min.
0 °C
Horizontal installation, max.
45 °C; possible with forced ventilation
Vertical installation, min.
0 °C
Vertical installation, max.
45 °C
Permissible range, min.
795 hPa
Permissible range, max.
1 080 hPa
Operation, min.
5 %
Operation, max.
95 %; RH class 2 in accordance with IEC 1131-2
Operation, checked according to iec 60068-2-6
Yes; IEC 68, Part 2-6; 10 to 58 Hz; (constant amplitude 0.075 mm); 58 to 500 Hz; (constant acceleration 9.8 m/s2)
Checked according to iec 60068-2-29
Yes; IEC 68, Part 2-29 half-sine: 100 m/s2 (10 g), 16 ms, 100 shocks
Step 7
Yes
Step 7 mini
Yes
Protool
Yes
Protool/pro
Yes
Command set
see instruction list
Nesting levels
8
Program organization
Linear, structured
System functions (sfc)
see instruction list
Lad
Yes
Fbd
Yes
Stl
Yes
Scl
Yes
Cfc
Yes
Graph
Yes
Higraph®
Yes
Process diagnostics
Yes; S7-CPU and C7-OP
Software controller
Yes; 16 circles
User program protection/password protection
Yes
Preset
150 ms
Number of online/runtime languages
3
Width
240 mm
Height
168 mm
Depth
69 mm
Mounting cutout, width
231 mm
Mounting cutout, height
159 mm
Weight, approx.
1 780 g
Last modified:
25.09.2014
Subcategoría
Plc
Subcategoría 2
Siemens plc all
Subcategoría 3
C7/rack pc,box pc
ID de Anuncio
98032487

Descripción

SIEMENS C7/RACK PC,BOX PC 6ES76262DG040AE3 SIMATIC C7-626/P DP, COMP. UNIT,WITH INTEGRATED COMPONENTS:,S7-300 CPU 315 2DP (128 KB),,SIMATIC OP25 AND IM 360,,16 DI, 16 DO, 4 AI, 4AO, 4 UISIMATIC C7-626/P DP,KOMP.GERAET,MIT INTEGRIERTEN KOMPONENTEN:,S7-300

Contactar al vendedor

Fabricante
N/A
Modelo
6ES7626-2DG04-0AE3
Ubicación
🇨🇳 Shenzhen, Guangdong, China

¿Le interesa esta máquina?

Capacidad de respuesta del vendedor: