6ES7635-2EC02-0AE3 C7-635 KEYS, 24 DI, 16 DO, 5 AI, 2 AO en Shenzhen, Guangdong, China
Nuevo
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- nuevo
- Artikelnummer
- 6ES7635-2EC02-0AE3
- 24 v dc
- Yes
- Permissible range, lower limit (dc)
- 20.4 V
- Permissible range, upper limit (dc)
- 28.8 V
- Rated value (dc)
- 24 V
- From load voltage l (without load), max.
- 70 mA
- From load voltage l , max.
- 100 mA
- Power loss, typ.
- 14 W
- Integrated
- 1
- Expandable
- No
- Plug-in (mmc)
- Yes
- Plug-in (mmc), max.
- 8 Mbyte
- Present
- Yes
- Without battery
- Yes; Program and data
- For bit operations, typ.
- 0.1 µs
- For bit operations, max.
- 0.2 µs
- For word operations, typ.
- 0.2 µs
- For fixed point arithmetic, typ.
- 2 µs
- For floating point arithmetic, typ.
- 3 µs
- Number, max.
- 511
- Size, max.
- 16 kbyte
- Number of free cycle obs
- 1; OB 1
- Number of time alarm obs
- 1; OB 10
- Number of delay alarm obs
- 1; OB 20
- Number of time interrupt obs
- 1; OB 35
- Number of process alarm obs
- 1; OB 40
- Number of startup obs
- 1; OB 100
- Number of asynchronous error obs
- 5; OB 80, 82, 85, 86, 87
- Per priority class
- 8
- Additional within an error ob
- 4
- Number
- 1
- Adjustable
- Yes
- Lower limit
- 48 Ω
- Upper limit
- 4 kΩ
- Preset
- No retentivity
- Retentivity available
- Yes; MB 0 to MB 255
- Retentivity preset
- MB 0 to MB 15
- Number of clock memories
- 8; 1 memory byte
- Per priority class, max.
- 510 byte
- Inputs
- 244 byte
- Outputs
- 244 byte
- Inputs, of which central
- 253
- Outputs, of which central
- 250
- Via cp
- 4
- Fm
- 8
- Cp, point-to-point
- 8
- Cp, lan
- 10
- Racks, max.
- 4
- Modules per rack, max.
- 8; In rack 3 max. 7
- Hardware clock (real-time clock)
- Yes
- Battery-backed and synchronizable
- Yes
- Deviation per day, max.
- 10 s
- Backup time
- 6 wk; At 40 °C ambient temperature
- Number/number range
- 0
- Range of values
- 0 to 2^31 hours (when using SFC 101)
- Granularity
- 1 hour
- Retentive
- Yes; Must be restarted at each restart
- Supported
- Yes; via CP and loadable FC
- To mpi, master
- Yes
- To mpi, slave
- Yes
- In as, master
- Yes
- Number of digital inputs
- 24
- Of which inputs usable for technological functions
- 16
- Integrated channels (di)
- 24
- Input characteristic curve in accordance with iec 61131, type 1
- Yes
- Up to 40 °c, max.
- 2 A
- Up to 60 °c, max.
- 12
- Rated value, dc
- 24 V
- For signal "0"
- -3 to 5 V
- For signal "1"
- 15 to 30 V
- For signal "1", typ.
- 9 mA
- Parameterizable
- Yes; by software
- Rated value
- 3 ms
- At "0" to "1", max.
- 8 µs
- Cable length, shielded, max.
- 200 m
- Cable length unshielded, max.
- 600 m
- Shielded, max.
- 1 000 m
- Unshielded, max.
- 600 m
- Number of digital outputs
- 16
- Of which high-speed outputs
- 4
- Integrated channels (do)
- 16
- Short-circuit protection
- Yes; Clocked electronically
- Response threshold, typ.
- 1 A
- Limitation of inductive shutdown voltage to
- L (-48 V)
- Controlling a digital input
- Yes
- Lamp load, max.
- 5 W
- For signal "1", min.
- L (-0.8 V)
- For signal "1" rated value
- 500 mA
- For signal "1" permissible range, min.
- 5 mA
- For signal "1" permissible range, max.
- 0.6 A
- For signal "1" minimum load current
- 5 mA
- For signal "0" residual current, max.
- 0.5 mA
- For uprating
- No
- For redundant control of a load
- Yes
- With resistive load, max.
- 100 Hz
- With inductive load, max.
- 0.5 Hz
- On lamp load, max.
- 100 Hz
- Of the pulse outputs, with resistive load, max.
- 2.5 kHz
- Integrated channels (ai)
- 4 1
- Number of analog inputs for voltage/current measurement
- 4
- Number of analog inputs for resistance/resistance thermometer measurement
- 1
- Permissible input voltage for current input (destruction limit), max.
- 2.5 V; Permanent
- Permissible input voltage for voltage input (destruction limit), max.
- 30 V; Permanent
- Permissible input current for voltage input (destruction limit), max.
- 0.5 mA; Permanent
- Permissible input current for current input (destruction limit), max.
- 50 mA; Permanent
- Technical unit for temperature measurement adjustable
- Yes; Degrees Celsius / degrees Fahrenheit / Kelvin
- Current
- Yes
- Resistance thermometer
- Yes
- Resistance
- Yes
- 0 to 10 v
- Yes
- Input resistance (0 to 10 v)
- 100 kΩ
- 10 v to 10 v
- Yes
- Input resistance (-10 v to 10 v)
- 100 kΩ
- 0 to 20 ma
- Yes
- Input resistance (0 to 20 ma)
- 50 Ω
- 20 to 20 ma
- Yes
- Input resistance (-20 to 20 ma)
- 50 Ω
- 4 to 20 ma
- Yes
- Input resistance (4 to 20 ma)
- 50 Ω
- Pt 100
- Yes
- Input resistance (pt 100)
- 10 MΩ
- No-load voltage, typ.
- 2.5 V
- Measuring current, typ.
- 1.8 to 3.3 mA
- 0 to 600 ohm
- Yes
- Input resistance (0 to 600 ohm)
- 10 MΩ
- For resistance thermometer
- Pt 100
- Number of analog outputs
- 2
- Integrated channels (ao)
- 2
- Voltage output, short-circuit protection
- Yes
- Voltage output, short-circuit current, max.
- 55 mA
- Current output, no-load voltage, max.
- 17 V
- 10 to 10 v
- Yes
- For voltage output two-wire connection
- Yes; Without compensation of the line resistances
- For voltage output four-wire connection
- No
- For current output two-wire connection
- Yes
- With voltage outputs, min.
- 1 kΩ
- With voltage outputs, capacitive load, max.
- 0.1 µF
- With current outputs, max.
- 300 Ω
- With current outputs, inductive load, max.
- 0.1 mH
- Voltages at the outputs towards mana
- 16 V; Permanent
- Current, max.
- 50 mA; Permanent
- Measurement principle
- Actual value encryption (successive approximation)
- Resolution with overrange (bit including sign), max.
- 12 bit
- Integration time, parameterizable
- Yes; 2,5 / 16,6 / 20 ms
- Permissible input frequency, max.
- 400 Hz
- Conversion time (per channel)
- 1 ms
- Time constant of the input filter
- 0.38 ms
- Basic execution time of the module (all channels released)
- 1 ms
- For resistive load
- 0.6 ms
- For capacitive load
- 1 ms
- For inductive load
- 0.5 ms
- For voltage measurement
- Yes
- For current measurement as 2-wire transducer
- Yes; with external supply
- For current measurement as 4-wire transducer
- Yes
- For resistance measurement with two-wire connection
- Yes; Without compensation of the line resistances
- For resistance measurement with three-wire connection
- No
- For resistance measurement with four-wire connection
- No
- 2-wire sensor
- Yes
- Permissible quiescent current (2-wire sensor), max.
- 1.5 mA
- Temperature error (relative to input range), ( /-)
- 0.006 %/K
- Crosstalk between the inputs, min.
- 60 dB
- Repeat accuracy in steady state at 25 °c (relative to input area), ( /-)
- 0.06 %
- Output ripple (based on output area, bandwidth 0 to 50 khz), ( /-)
- 0.1 %
- Linearity error (relative to output range), ( /-)
- 0.15 %
- Temperature error (relative to output range), ( /-)
- 0.01 %/K
- Crosstalk between the outputs, min.
- 60 dB
- Repeat accuracy in steady state at 25 °c (relative to output area), ( /-)
- 0.06 %
- Voltage, relative to input area, ( /-)
- 0.7 %; Linearity error /- 0.06 %
- Current, relative to input area, ( /-)
- 0.7 %; Linearity error /- 0.06 %
- Resistance, relative to input area, ( /-)
- 3 %; Linearity error /- 0.2%
- Voltage, relative to output area, ( /-)
- 0.7 %
- Current, relative to output area, ( /-)
- 0.7 %
- Resistance thermometer, relative to input area, ( /-)
- 3 %
- Series mode interference (peak value of interference < rated value of input range), min.
- 30 dB
- Common mode interference, min.
- 40 dB
- Mpi
- No
- Cable length, max.
- 50 m; without repeater
- Interface type
- Integrated RS 485 interface
- Physics
- RS 485
- Isolated
- Yes
- Power supply to interface (15 to 30 v dc), max.
- 200 mA
- Point-to-point connection
- No
- Transmission rate, max.
- 12 kbit/s
- Pg/op communication
- Yes
- Routing
- Yes
- S7 communication, as client
- No
- S7 communication, as server
- Yes
- Number of connection resources
- 12
- Number of connections, max.
- 12; For PG/OP communication
- Number of connections (of which reserved), max.
- 1 for PG, 1 for OP
- Number of dp slaves, max.
- 32
- Equidistance mode support
- Yes
- Sync/freeze
- Yes
- Activation/deactivation of dp slaves
- Yes
- Direct data exchange (slave-to-slave communication)
- Yes
- Dpv1
- No
- Inputs, max.
- 244 byte
- Outputs, max.
- 244 byte
- Gsd file
- The latest GSD file is available at:
- Address area, max.
- 32
- User data per address area, max.
- 32 byte
- Number of gd loops, max.
- 4
- Number of gd packets, max.
- 4
- Number of gd packets, transmitter, max.
- 4
- Number of gd packets, receiver, max.
- 4
- Size of gd packets, max.
- 22 byte
- Size of gd packet (of which consistent), max.
- 22 byte
- User data per job, max.
- 180 kbyte; With PUT/GET
- User data per job (of which consistent), max.
- 64 byte
- As server
- Yes
- As client
- Yes; Via CP and loadable FB
- Overall
- 12
- Usable for pg communication
- 11
- Reserved for pg communication
- 1
- Adjustable for pg communication, min.
- 1
- Adjustable for pg communication, max.
- 11
- Usable for op communication
- 11
- Reserved for op communication
- 1
- Adjustable for op communication, min.
- 1
- Adjustable for op communication, max.
- 11
- Usable for s7 basic communication
- 8
- Reserved for s7 basic communication
- 8
- Adjustable for s7 basic communication, min.
- 0
- Adjustable for s7 basic communication, max.
- 8
- Usable for routing
- 4; max.
- Number of login stations for message functions, max.
- 12; Depending on the configured connections for PG/OP and S7 basic communication
- Process diagnostic messages
- Yes
- Simultaneously active alarm-s blocks, max.
- 40
- Status block
- Yes
- Single step
- Yes
- Number of breakpoints
- 2
- Status/control variable
- Yes
- Variables
- Inputs, outputs, memory bits, DB, times, counters
- Number of variables, max.
- 30
- Of which status variables, max.
- 30
- Of which control variables, max.
- 14
- Forcing
- Yes
- Number of entries, max.
- 100
- Number of counters
- 4; See "Technological Functions" manual
- Counting frequency (counter) max.
- 60 kHz
- Frequency measurement
- Yes
- Number of frequency meters
- 4; up to 60 kHz (see "Technological Functions" manual)
- Controlled positioning
- Yes
- Integrated function blocks (closed-loop control)
- PID controller (see "Technological Functions" manual)
- Pid controller
- Yes
- Number of pulse outputs
- 4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual)
- Limit frequency (pulse)
- 2.5 kHz
- Galvanic isolation digital inputs
- Yes
- Between the channels
- No
- Between the channels and the backplane bus
- Yes
- Galvanic isolation digital outputs
- Yes
- Between the channels, in groups of
- 8
- Galvanic isolation analog inputs
- Yes; common for analog I/O
- Galvanic isolation analog outputs
- Yes; common for analog I/O
- Between different circuits
- 75 VDC / 60 VAC
- Between inputs and mana (ucm)
- 8 V DC
- Between mana and m internally (uiso)
- 75 VDC / 60 VAC
- Isolation tested with
- 500 V DC
- Step 7
- Yes; V5.2 SP1 with HW update
- Command set
- see instruction list
- Nesting levels
- 8
- System functions (sfc)
- see instruction list
- System function blocks (sfb)
- see instruction list
- Lad
- Yes
- Fbd
- Yes
- Stl
- Yes
- Scl
- Yes
- Cfc
- Yes
- Graph
- Yes
- Higraph®
- Yes
- User program protection/password protection
- Yes
- Width
- 260 mm
- Height
- 273.8 mm
- Depth
- 80 mm
- Mounting cutout, width
- 231 mm
- Mounting cutout, height
- 257 mm
- Weight, approx.
- 1 500 g
- Last modified:
- 31.07.2014
- Subcategoría
- Plc
- Subcategoría 2
- Siemens plc all
- Subcategoría 3
- C7/rack pc,box pc
- ID de Anuncio
- 88363499
Descripción
SIEMENS C7/RACK PC,BOX PC 6ES76352EC020AE3 SIMATIC C7-635 KEYS,,COMPACT UNIT,WITH INTEGRATED COMPONENTS:,S7-300 CPU314C-2 DP AND OP170B,,24 DI, 16 DO, 5 AI, 2 AO;,MICRO MEMORY CARD AND,CONNECTOR SET REQUIREDSIMATIC C7-635 TASTEN,,KOMPLETTGERAET,MIT INTEGR
¿Le interesa esta máquina?
Este vendedor fue contactado 1 vez durante la semana anterior.