HK-368 Inductive Concentration/Conductivity Analyzer en Pekín, China
Nuevo
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- nuevo
- Material code
- HK-368
- Manufacturers.
- hky technology co.,ltd.
- ◆ communication
- RS485/PROFIBUS-DP/HART, choose one.
- Transmitter
- 1 set
- Sensor
- 1 set
- Installation component
- 1 set (choose one)
- Display.
- Chinese/ English, TFT color LCD
- Measurement range.
- Conductivity: NaOH : HCl : NaCl : H2SO4 : HNO3 : Salinity : TDS:
- Measuring medium.
- NaOH, HCl, NaCl, H2SO4, HNO3
- Resolution.
- Conductivity: 1mS/cm; Concentration: 0.01%
- Error.
- Conductivity: 2% FS; Concentration: ±5% FS
- Repeatability.
- ±0.5FS%
- Stability.
- ±1.0% FS/30min
- Temperature sensor.
- PT1000
- Temperature accuracy.
- ±1℃
- Temperature solution.
- 0.1℃
- Temperature compensation range.
- (0~55)℃
- Current output.
- (0~10)mA, (0~20)mA or (4~20)mA (Dual-channel independent isolated output), optional. load: 600Ω, Error: 0.1mA
- Communication.
- RS485, Profibus or Hart (optional)
- Relay output.
- Dual-channel configurable
- Storage.
- ≥100,000
- Response time.
- ≤30s
- Sample temperature.
- (0~40)℃
- Working pressure of flow cell sensor.
- ≤0.25MPa
- Medium flow of flow cell sensor.
- (6~20)L/h
- Solid contents in sample.
- ≤5μm (no gel and grease)
- Power supply.
- AC(100~240)V, (50~60)Hz
- Ambient humidity.
- ≤90% RH (No condensation)
- Safety requirement
- Leakage Current
- Ground resistance
- ≤0.5Ω
- Insulation resistance
- The insulation resistance of the power phase and the neutral line of the electronic unit to the ground ≥ 40MΩ.
- Dielectric strength
- Between the power phase, neutral line and ground, and between the power input terminal and the metal parts that may be touched, it should be able to withstand a test voltage of AC 1500V, 50Hz for 1min, and there should be no electric breakdown or arcing.
- Static test
- For the air discharge test, apply 8kV voltage to the panel, shell, cable, and interval 1min. For the contact discharge test, apply 6kV voltage to the panel, shell, cable, and interval 1min. For the contact discharge test, apply 6kV voltage to the panel, shell, cable, and interval 1min.
- Transmitter overall dimension.
- 146mm*146mm
- Sensor overall dimension.
- 146mm*146mm*146mm
- Sensor cable length.
- 5m (Special requirements can be customized before ordering)
- Keypad.
- 8 keys
- Installation method.
- Panel-mounting, Wall-mounting, Pipe-mounting
- Power consumption.
- ≤8W
- Weight.
- 5kg
- Flow cell: 1 set
- Flange: 1 set
- Categoría
- Tratamiento de aguas en China
- Subcategoría
- Online water analyzer
- ID de Anuncio
- 86854956
Descripción
HK-368 Inductive Concentration/Conductivity Analyzer is an online industrial analyzer. The sensor adopts corrosion-resistant material and contact-free detection mode, which can effectively prevent the sensor from being corroded, polluted and polarized effect by the corrosive medium. The sensor adopts corrosion-resistant material and contact-free detection mode, which can effectively prevent the sensor from being corroded, polluted and polarized effect by the corrosive medium.