Maxilog Alert Multi-Use en Dallas, Texas, USA

Especificaciones

Condición
usado
Número de stock
8018-M
Standard temperature range
-29°C to +72°C / -20°F to +162°F
Low temperature range
-80°C to +30°C / -113°F to +86°F
Memory
32K
Software
c/temp+ (read only) | MDAS Pro (user configurable) | 21 CFR-DB (21 CFR Part 11 Compliant)
Recording type
Single-Use(may be overwritten prior to starting unit), Multi-Use; Single-Use(may be overwritten prior to starting unit), Multi-Use; Single Use
Temperature measurement range
-29°C to +72°C /; -20°F to +162°F; -80°C to +30°C /; -113°F to +86°F; -30°C to +70°C /; -22°F to +158°F
Temperature accuracy range
±0.2°C at 0°C to 10°C,; ±0.9°C at extremes /; ±.36°F at 32°F to 50°F,; ±1.8°F at extremes; ±0.5°C at 0°C to 10°C,; ±2.0°C at extremes /; ±0.9°F at 32°F to 50°F,; ±3.6°F at extremes; ±0.3°C / 0.54°F
Temperature resolution
0.1°C / 1.8°F; 0.1°C / 1.8°F; 0.1°C / 1.8°F
Data storage capacity
32K with up to 31,980 data points; 32K with up to 31,980 data points; 14K with up to 14,400 data points
Battery life / type
CR2032 Lithium coin cell, 1 yr operating life,; 2 yr shelf life; ER2450T,; 1 yr operating life, 2 yr shelf life; CR2032 Lithium coin cell, 18 month shelf life
Data sampling interval
2 seconds to 36 hours; 2 seconds to 36 hours; 10 Minutes
Start up delay
2 seconds to 36 hours; 2 seconds to 36 hours; 30 Minutes
Alarm programming
Programmable high and low limits. Alarm triggered when limits are exceeded for specified time period.; Programmable high and low limits. Alarm triggered when limits are exceeded for specified time period.; Programmable highand low limits. Alarm trigged when limits exceeded.
Alarm modes
Exceed Limit,Continuous Interval, Cumulative; Exceed Limit,Continuous Interval, Cumulative; Exceed Limit
Alarm reset options
Single Use: No reset option Multi-Use: Alarm is reset when loggeris erased and reprogrammed; Single Use: No reset option Multi-Use: Alarm is reset when loggeris erased and reprogrammed; Single Use: No reset option
Alarm notifications
Red LED flashes when alarm has been triggered; Red LED flashes when alarm has been triggered; Red LED flashes when alarm has been triggered
Indicators
LED Indicators:on/recording (green), alarm (red flash); LED Indicators:on/recording (green), alarm (red flash); LED Indicators:on/recording (green), alarm (red flash)
Start up options
Push buttonautomatic start with optional delay; Push buttonautomatic start with optional delay; Push button: Start/Mark/Stop
Dimensions
8.8 cm (l) x 3.49 cm (w) x; 1.58 cm (h) / 3.5 in (l) x; 1.38 in (w) x 0.62 in (h); 8.8 cm (l) x 3.49 cm (w) x; 1.58 cm (h) / 3.5 in (l) x; 1.38 in (w) x 0.62 in (h); 94mm (h) x 20 mm (w) x 7 mm (h) / 3.7 in (l) x; 0.8 in (w) x 0.27 in (h)
Weight
65 g / 3.0 oz; 65 g / 3.0 oz; 10.6 g / 0.37 oz.
Quality assurance certifications
CE, NIST Traceable, Certificate of Calibration; CE, NIST Traceable, Certificate of Calibration; CE, NIST Traceable, Certificate of Calibration
Minimum system requirements
Windows XP, Vista: 7, 8 and 10; Windows XP, Vista: 7, 8 and 10; Windows XP, Vista: 7, 8 and 10, MAC and Android
Required software
c\temp+ (read only) | MDAS-Pro, 21 CFR (user configurable); c\temp+ (read only) | MDAS-Pro, 21 CFR (user configurable); PDF Reader
Computer interface
USB A, built-in interface; USB A, built-in interface; USB A, built-in interface
Warranty
1 Year; 1 Year; 1 Year
Subcategoría
Data loggers
Subcategoría 2
Condition monitors
ID de Anuncio
108699970

Descripción

Multi-use data logger with a temperature range of 29°C to +72°C / -20°F to +162°F
Details
Applications
Specifications
Product Numbers

Software
In a convenient palm-sized design, the MaxiLog Alert combines robust temperature monitoring with simple data retrieval via built-in USB interface with direct download to software. Available for standard and low temperature monitoring, these single and multi-use loggers are complete with options to customize start time delay, sampling intervals, high and low alarm values, alarm type and measurement data.
Floral
Specimens
Chocolate
Tissue samples
Pharmaceutical
Meal delivery
Raw and cooked meats
Chemicals
Standard Temperature Item Numbers: 8018-S MaxiLog Alert Single-Use | 8018-M MaxiLog Alert Multi-Use
Low Temperature (Dry Ice) Item Numbers: 8114-S MaxiLog Alert -80C Single-Use | 8114-M MaxiLog Alert -80C Multi-Use
SpotSee
8018-S MaxiLogAlert Single-Use 8018-MMaxiLog Alert Multi-Use
SpotSee

$40 USD

Fabricante
N/A
Ubicación
🇺🇸 Dallas, Texas, USA

¿Le interesa esta máquina?

Vendedor de confianza

5