Building Filters
2015 ISUZU GIGA -29 degree setting refrigerated freezer truck 4-axis low floor
- Fabricante: Isuzu
- Modelo: GIGA
- Kilometraje: 513,721.37571999995 mile
- Tipo de combustible: diesel
Division: Large-scale | Engine model: 6UZ1 | Load capacity: 10,500kg | Mileage: 826,756km | Exhaust: 9,830cc | Total weight of vehicle: 22,960kg | Fuel: Diesel | Size of vehicle: 1,198cm × 250cm × 379cm | Option:...
Takamatsu, JapónPTFM-1000V2
- Fabricante: HORIBA UK Limited
Test vehicle/engine: Diesel (HDD, LDD), Gasoline, LPG and CNG vehicles, Ethanol, Propane, Butane | Configuration: Interface unit connected to pitot tube via umbilical cable. Pitot tube can be standard (0 - 230ºC)...
Kioto, JapónHI-700 II
Capacity: Max 6 kg; Max 6 kg; Max 12kg | Single interval: e= 1g; e= 2g (660mm scale); e= 2g | Pack speed: up to 120 packs per minute | Pack size: 475mm scale; L80-300mm x W40-250mm x H180mm | Screen: 15" Colour L...
Tokio, JapónMEXA-1170SX
- Fabricante: HORIBA, Ltd.
Components: SO 2 , TRS * , Both SO 2 and TRS simultaneously and Total-S * Total reduced sulfur | Principle: Ultra-viiolet fluorescence | Sample gas flow rate: SO 2 , TRS Approx. 5 l/min | Linearity: SO 2 , SUM, T...
Kioto, JapónHiTESTER 3030-10
Dc voltage range: 0.3 V (16.7 kΩ/V), 3/12/30/120/300/600 V (20 kΩ/V) Accuracy: ±2.5 % f.s. Max. rated voltage: 600 V | Ac voltage range: 12 V (9 kΩ/V) Accuracy: ±4 % f.s. 30/120/300/600 V (9 kΩ/V) Accuracy: ±2.5 ...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HF-700A
- Fabricante: Horiba
Model name: HF-700A | Measurement method: Fluoride ion electrode method | Measurement range: 0 - 1000mg/L (0 - 100/200/500/1000mg/L) | Repeatability: Within +/- 2% of the full scale | Stability: Within +/- 2% of ...
Kioto, JapónANALOG MΩ HiTESTER IR4018
- Fabricante: HIOKI E.E
Rated output voltage: 1000 V DC | Effective maximum indicated value: 2000 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length, 2 M to 1000 MΩ | Lower limit resistance: 1 MΩ (measurement resistance v...
Nagano, JapónANALOG MΩ HiTESTER IR4017
- Fabricante: HIOKI E.E
Rated output voltage: 500 V DC | Effective maximum indicated value: 1000 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length, 1 M to 500 MΩ | Lower limit resistance: 0.5 MΩ (measurement resistance v...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HE-480R
- Fabricante: Horiba
Product name: industrial resistance meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃ | Repeatability: Wit...
Kioto, JapónANALOG MΩ HiTESTER IR4016
- Fabricante: HIOKI E.E
Rated output voltage: 500 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length, 0.1 M to 50 MΩ | Lower limit resistance: 0.5 MΩ (measurement resistance v...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HZ-960HPO-M
- Fabricante: Horiba
Chemical contact material of detector: PFA, PTFE, quartz glass | Supply pressure: Within 0.5 MPa | Repeatability: +/- 0.2% of full scale | Linearity: +/- 1.0% of full scale | Transmission output: Number of output...
Kioto, JapónANALOG MΩ HiTESTER 3490
- Fabricante: HIOKI E.E
Rated output voltage: 250 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length 0.05 to 50 MΩ | Lower limit resistance: 0.25 MΩ | Overload protection: 660...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HZ-960
- Fabricante: Horiba
Chemical contact material of detector: PFA, PTFE, quartz glass | Supply pressure: Within 0.5 MPa | Repeatability: +/- 0.2% of full scale | Linearity: +/- 1.0% of full scale | Transmission output: Number of output...
Kioto, JapónAll-In-One Bulk System
Capacity: Model; Resolution; Weighing Range; Deviation | Max 1.5kg: Hopper Scale; 1 / 1,000; 0 - 0.5kg; e = 0.5g | 1 / 1,500: 0.5 - 1.5kg; e = 1g | Max 30kg: Scoop and Liquid Scale; 1 / 6,000; 0 - 30kg; e = 5g | ...
Tokio, JapónHORIBA, Ltd. 51 series
- Fabricante: Horiba
Measuring principle: Non-Dispersive Infrared Absorption Method (NDIR) | Component: CO, CO 2 , CH 4 , etc. *1 | Span ±0.5% of full scale: Span : ±1.0% of full scale | Linearity: ±1.0% of full scale | Optional ran...
Kioto, Japón