Building Filters
DIGITAL MULTIMETER DT4253
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, JapónDIGITAL MULTIMETER DT4281
Dc voltage range: 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | Ac voltage(*1) range: 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 ...
Nagano, JapónDIGITAL MULTIMETER DT4282
Dc voltage range: 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | Ac voltage(*1) range: 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 ...
Nagano, JapónVIR GENERATOR UNIT U8794
- Fabricante: HIOKI E.E
Output terminal: Number of channels: 8 (each channel is isolated), Connector: 25-pin D-sub Max. rated voltage to earth: 25 V | Output items: DC voltage, DC current, resistance (simulated output) | Output range: D...
Nagano, JapónC HiTESTER 3504
Measurement parameters: C (capacitance), D (loss coefficient tan δ) | Measurement range: C: 0.9400 pF to 20.0000 mF, D: 0.00001 to 1.99999 | Basic accuracy: (Typ.) C: ±0.09 % rdg. ±10 dgt., D: ±0.0016 | Measur...
Nagano, JapónSUPER MEGOHM METER SM7120
Number of channels: 1 ch | Dc current measurement: 20 pA range (0.1 fA resolution), Accuracy: ±(2.0 % of rdg. +30 dgt.) 200 pA range (1.0 fA resolution), Accuracy: ±(1.0 % of rdg. +30 dgt.) 2 nA range (10 fA re...
Nagano, JapónSUPER MEGOHM METER SM7110
Number of channels: 1 ch | Dc current measurement: 20 pA range (0.1 fA resolution), Accuracy: ±(2.0 % of rdg. +30 dgt.) 200 pA range (1.0 fA resolution), Accuracy: ±(1.0 % of rdg. +30 dgt.) 2 nA range (10 fA re...
Nagano, JapónFLYING PROBE TESTER FA1240-6x
- Fabricante: HIOKI E.E
Number of arms: 4 (L, ML, MR, R) | Number of test steps: 40,000 (max.) | Measurement ranges: Resistance: 400 μΩ to 40 MΩ Capacitance: 1 pF to 400 mF Inductance: 1 μH to 100 H Diode VZ measurement: 0 to 25 V Zener...
Nagano, JapónAC/DC CURRENT PROBE CT6844A
Rated current: 500 A AC/DC | Frequency bandwidth: DC to 500 kHz | Diameter of measurable conductors: Max. φ 20 mm (0.79 in.) | Max. allowable input: ±800 A peak (Within 20 ms in an environment of 40°C/104°F or le...
Nagano, JapónAC/DC CURRENT PROBE CT6843A
Rated current: 200 A AC/DC | Frequency bandwidth: DC to 700 kHz | Diameter of measurable conductors: Max. φ 20 mm (0.79 in.) | Max. allowable input: ±600 A peak (Within 20 ms in an environment of 40°C/104°F or le...
Nagano, JapónAC/DC CURRENT PROBE CT6845A
Rated current: 500 A AC/DC | Frequency bandwidth: DC to 200 kHz | Diameter of measurable conductors: Max. φ 50 mm (1.97 in.) | Max. allowable input: ±1500 A peak (Within 20 ms in an environment of 40°C/104°F or ...
Nagano, JapónAC/DC CURRENT PROBE CT6846A
Rated current: 1000 A AC/DC | Frequency bandwidth: DC to 100 kHz | Diameter of measurable conductors: Max. φ 50 mm (1.97 in.) | Max. allowable input: ±1900 Apeak (Within 20 ms in an environment of 40°C/104°F or l...
Nagano, JapónAC/DC CURRENT PROBE CT6841A
Rated current: 20 A AC/DC | Frequency bandwidth: DC to 2 MHz | Diameter of measurable conductors: Max. φ 20 mm (0.79 in.) | Max. allowable input: ±60 A peak (Within 20 ms in an environment of 40°C/104°F or less)...
Nagano, JapónDIGITAL MULTIMETER DT4223
Dc voltage range: 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±1.0 % ...
Nagano, JapónAC/DC CURRENT SENSOR CT7631
Rated measurement current: 100 A AC/DC | Max. measurement current: 100 A (requires derating at frequency)) | Max. allowable peak input: 150 A peak | Bandwidth: DC to 10 kHz (-3dB) (When used in combination with ...
Nagano, Japón