Building Filters
GFLZZ0746-10GY 2000A/5A wound type medium voltage current transformer
Standards: IEC60044; IEC 61869; ANSI/IEEE C57.13 | Rated primary current: 5-3150A | Rated load: ≤60VA | Rated frequency: 50Hz or 60Hz | Rated secondary current: 5A or 1A | Rated short-time thermal current: 120kA,...
Pekín, ChinaLZCK-55 clamp outdoor waterproof split core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; GB/T20840.2; ANSI/IEEE C57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% | Range of primary rated current: 100-1000A | Range of rated load: ≤10VA | Rated fre...
Pekín, ChinaGFLZZ0954-10E presicion ANSI 5A CTs current transformer supplier
Normas: IEC60044; IEC 61869; ANSI/IEEE C57.13 | Corriente primaria nominal: 5-1250A | Carga nominal: ≤15 VA | Frecuencia nominal: 50 Hz o 60 Hz | Corriente secundaria nominal: 5 A o 1 A | Corriente térmica nomina...
Pekín, ChinaFU120 low voltage bus bar type split core current transformer
Standards: IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 | Accuracy: 0.2%, 0.5%, 1% | Ratio: 601, 1201, 3000/5A or 10001, customized | Nominal input current (primary current): 300A/400A/500A/600A/750A/800A/...
Pekín, ChinaLMCK185-10 IP65 waterproof split core outdoor current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; GB/T20840.1 & 2; ANSI/IEEE C57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% (IEC61869 standard) | Range of primary rated current: 300-5000A | Range of rated...
Pekín, ChinaLZCT722-10 electrical cast resin zct zero sequence current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Class: 0.2S, 0.2, 0.5S, 0.5, 1, 3, 10P10, 10P, 10P20 | Rated primary current: 50-1500A | Rated load: ≤25VA | Rated frequency: 50Hz or...
Pekín, ChinaLZCG530-10 11KV cast epoxy resin straight-through current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Accuracy class: 0.2S, 0.2, 0.5S, 0.5 (IEC61869 standard) | Rated primary current: 30-1000A | Rated load: ≤20VA | Rated frequency: 50H...
Pekín, ChinaLZCK2500-10 high accuracy 33KV split core zero phase current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Class: 0.5, 1, 3, 10P10, 10P5, 10P20 | Rated primary current: 50-2000A | Rated load: ≤25VA | Rated frequency: 50Hz or 60Hz | Rated se...
Pekín, ChinaLZCK322-10 11KV 33KV high voltage split core CT current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006; | Class: 0.5, 1, 3 | Rated primary current: 30-1000A | Rated load: ≤15VA | Rated frequency: 50Hz or 60Hz | Rated secondary current: 5A or 1A...
Pekín, ChinaT-213 Transformer winding DC resistance tester
Power supply: Single phase AC 220V±10% or 110V±10% , 50/60Hz AC | Cooling way: Intermittent air cooled | Current output: 10mA, 100mA, 1A, 5A, 10A, 20A | Test voltage: DC 28V | Test range: 1mΩ-1Ω (20A) | Accuracy:...
Pekín, China- Pekín, China
LZCK350-10 100/5A epoxy resin cast split core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Rated primary current: 30-1000A | Rated load: ≤25VA | Rated frequency: 50Hz or 60Hz | Rated secondary current: 5A or 1A | Rated short...
Pekín, ChinaFU-16 economic 333mv mini split core current transformer for meter
Standards: IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 | Accuracy: 0.2%, 0.5%, 1% | Ratio: 10001 or 20001, customized | Nominal input current (primary current): 5A/10A/20A/30A/40A/50A/60A/80A/100A/150A/20...
Pekín, Chinalzck-120 outdoor 120mm window ip67 split core ct transformer
Standards: iec60044-1; iec 61869-2; ntc 2205; gb1208-2006; gb/t20840.1&2; ansi/ieee c57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% (IEC61869 standard) | Range of primary rated current: 300-3000A | Range of rated l...
Pekín, ChinaLZCK310-10 400/5a cheap split core cast resin current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006; | Class: 0.5, 1, 3 | Rated primary current: 300-1000A | Rated secondary current: 5A or 1A | Rated load: ≤10VA | Rated frequency: 50Hz or 60H...
Pekín, China