Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 - 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 - 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0 - 30 °C...
Kioto, JapónHORIBA Scientific VS70-HSR & VS70-HDR
- Fabricante: Horiba
Spectral coverage: Standard: UV-VIS (200–860 nm) with 477 l/mm grating, VIS (380–750 nm) with 582 l/mm grating, UV-NIR (200–1050 nm) with double-blazed 365 l/mm grating On request other spectral ranges available;...
Kioto, JapónTCA-5000
Measurement principle: Thermal conductivity detection method | Measurement range: (Min.) 0 - 10 vol% (Max.) 0 - 100 vol% | Measurement range (optional): 0 - 5 vol% to less than 10 vol% 100 - 90 vol...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUA EC1100 Conductivity/TDS/Res/Sal/Temp
- Fabricante: Horiba
Condutivity range: ...µS/cm to 2000 mS/cm | Resolution: 0.1°C | Accuracy: ± 0.4°C | Temperature coefficient: 0.00 to 10.00% (adjustable) | Cell constant: 0.1, 1.0, 10.0 (selectable) | Measurement unit: μS/cm, mS/...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUA PH1300 pH/ORP/Ion/Temperature
- Fabricante: Horiba
Ph range: -2.000 to 20.000 pH | Resolution: 0.1°C | Accuracy: ± 0.4°C | Calibration points: Up to 5 | Buffer options: USA, NIST, Custom | Orp range: ± 2000 mV | Ion range: 0.000 µg/L to 9999 g/L | Temperatur...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. OCMA-500
- Fabricante: Horiba
Product name: Oil content analyzer | Measurement method: Solvent extraction - non-dispersive infrared absorption analysis method | Measured objects: Substances extracted from sample water into solvent and having ...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. OCMA-550
- Fabricante: Horiba
Product name: Oil content analyzer | Measurement method: Solvent extraction - non-dispersive infrared absorption analysis method | Measured objects: Substances extracted from sample water into solvent and having ...
Kioto, JapónHORIBA Scientific VS70-PDA
- Fabricante: Horiba
Spectral coverage: Standard: UV-VIS (200–860 nm) with 477 l/mm grating, VIS (380–750 nm) with 582 l/mm grating, UV-NIR (200–1050 nm) with double-blazed 365 l/mm grating On request other spectral ranges available ...
Kioto, JapónMEXA-1170HFID
- Fabricante: HORIBA, Ltd.
Principle: Flame ionization detection (heated) | Ranges: 0-10 ppmC to 0-200,000 ppmC (Max. 14 ranges) | Response time(t90): Within 1.5 sec (by switching zero line and span line for calibration) | Repeatability: W...
Kioto, JapónUV300-5D
- Fabricante: Horiba
Sample flow: 0.05 - 1 l/min | Sample pressure: 0 - 4 Bar | Sample temperature: 0 - 50°C | Wet parts material: Quartz, Polypropylene, Polyethylene, FPM (viton), PMMA | Measuring time: 5 sec for turbidity, pH, cond...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUA PH1100 pH/ORP/Temperature
- Fabricante: Horiba
Ph range: -2.00 to 20.00 pH | Resolution: 0.1°C | Accuracy: ± 0.4°C | Calibration points: Up to 5 | Buffer options: USA, NIST | Orp range: ± 2000 mV | Temperature range: -30.0 to 130.0°C | Calibration option...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUA PC1100 Dual Channel pH/ORP/Cond/TDS/Res/Sal/Temp
- Fabricante: Horiba
Ph range: -2.000 to 20.000 pH | Resolution: 0.1°C | Accuracy: ±0.4°C | Calibration points: Up to 4 (Auto / Manual) | Buffer options: USA, NIST, Custom | Orp range: ± 2000 mV | Conductivity range: ...µS/cm to...
Kioto, JapónOBS-ONE-XL (IRLAM)
- Fabricante: HORIBA, Ltd.
Measurement target: Light and heavy duty vehicle engine exhaust gas | Components and range: NH 3 0 - 1500 ppm N 2 O 0 - 1000 ppm | Measurement principle: Quantum cascade laser infrared spectroscopy (QCL-IR) | Sam...
Kioto, JapónHyEVO
- Fabricante: HORIBA, Ltd.
Field: Application example | Environment / energy: Hydrogen combustion in hydrogen gas turbines, hydrogen boilers Hydrogen production through water electrolysis Development of fuel cells as power generation devic...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. LAQUA PH1200 pH/ORP/Temperature
- Fabricante: Horiba
Ph range: -2.000 to 20.000 pH | Resolution: 0.1°C | Accuracy: ± 0.4°C | Calibration points: Up to 5 | Buffer options: USA, NIST, Custom | Orp range: ± 2000 mV | Temperature range: -30.0 to 130.0°C | Calibrat...
Kioto, Japón