Yamato DS601
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +5 to 260°C | Temp. adjustment accuracy: ±1.0°C (at 260°C) | Temp. fluctuation: 3.0°C (at 260°C) | Temp. distribution accuracy: ±5.0°C (at 260°C)...
Tokio, JapónYamato DN411I
- Fabricante: Yamato
Method: Forced Convection | Operating temp. range: Room Temp. +15 to 360°C | Temp. adjustment accuracy: ±0.2℃(at 360℃) | Temp. fluctuation: 1.2℃(at 360℃) | Temp. uniformity: ±3℃(at 360℃) | Temp. gradient: 12℃(at ...
Tokio, JapónYamato DT300
- Fabricante: Yamato
Method: Forced air circulation | Operating temp. range: Room temp. +20°C to 300°C | Temp. control accuracy (jtm k05): ±0.3℃(at 100℃, 200℃, 300℃) | Temp. fluctuation (jis): 1.0°C (at 100 / 200°C) , 2.0°C (at 300°C...
Tokio, JapónYamato DE611
- Fabricante: Yamato
Temp. distribution accuracy: ±2.5°C (at 260°C) JTM K05 | Max. temp. reaching time: Approx. 70 min. (at 260°C) | Heater: Stainless pipe heater | Cable hole: 33mm I.D. ×1 | Timer: 1 min. to 99 Hrs. 59 min | Operati...
Tokio, JapónYamato DH612S
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temp. range: RT+10°C to 360°C | Temp. gradient: 12℃(at 360℃) | Temperature control: PID control with a micro computer | Operation & control: Fixed temp., Auto...
Tokio, JapónYamato DHS710
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~360℃ | Max. temp. reaching time: Approx. 50 min.(at 360℃) | Temperature adjustment accuracy: ±0.3℃(at 360℃) | Temperature dis...
Tokio, JapónYamato DH412S
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temp. range: RT+10°C to 360°C | Temp. gradient: 12℃(at 360℃) | Temperature control: PID control with a micro computer | Operation & control: Fixed temp., Auto...
Tokio, JapónYamato DFS810
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~260℃ | Max. temp. reaching time: Approx. 40 min.(at 260℃) | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature dis...
Tokio, JapónYamato DFS710
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~260℃ | Max. temp. reaching time: Approx. 40 min.(at 260℃) | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature dis...
Tokio, JapónYamato DF412S
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temp. range: RT+10°C to 260°C | Temp. gradient: 10℃(at 260℃) | Temperature control: PID control with a micro computer | Operation & control: Fixed temp., Auto...
Tokio, JapónYamato DF612S
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temp. range: RT+10°C to 260°C | Temp. gradient: 10℃(at 260℃) | Temperature control: PID control with a micro computer | Operation & control: Fixed temp., Auto...
Tokio, JapónYamato DF612
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 260℃ | Temp. control accuracy (jtm k05): ±0.1℃(at 260℃) | Temp. fluctuation (jis): 1.0℃(at 260℃) | Temp. distribution accuracy...
Tokio, JapónYamato DNE911
- Fabricante: Yamato
- Modelo: DNE911
Operating temp. range: Room temp. +15 to 210°C | Temp. adjustment accuracy: ±0.5°C (at 210°C) | Temp. distribution accuracy: ±2.0°C (at 210°C) | Max. temp. reaching time: Approx. 60 min. | Interior/exterior mater...
Tokio, JapónYamato DNE670V
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE611
- Fabricante: Yamato
Operating temp. range: Room temp. +20 to 210°C | Temp. adjustment accuracy: ±0.5°C (at 210°C) | Temp. distribution accuracy: ±2.0°C (at 210°C) | Max. temp. reaching time: Approx. 70 min. | Interior/exterior mater...
Tokio, Japón