Building Filters
POWER QUALITY ANALYZER PQ3100
Measurement line type: Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel CH4 for voltage/current, (all channels AC/DC measurement) | Voltage ranges: V...
Nagano, JapónCLAMP ON PROBE 3274
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 10 MHz (-3 dB) | Rise time: 35 ns or shorter | Noise level: 25 mA rms max. (bandwidth limited to 20 MHz) | Continuous allowable input: 150 A rms (requires derating at frequency) | Max. ...
Nagano, JapónPOWER METER PW3335
Measurement lines: Single-phase/ two-wires | Measurement items: Voltage, current, active power, apparent power, reactive power, power factor, phase angle, frequency, maximum current ratio, current integration, ac...
Nagano, JapónCURRENT PROBE CT6710
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 50 MHz (-3 dB) | Rise time: 7.0 ns or shorter | Delay time (typical): 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns (Delay time relative to rising waveform of input signal 1...
Nagano, JapónCURRENT PROBE CT6711
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 120 MHz (-3 dB) | Rise time: 2.9 ns or shorter | Delay time (typical): 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns (Delay time relative to rising waveform of input signal ...
Nagano, JapónCLAMP ON PROBE 3273-50
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 50 MHz (-3 dB) | Rise time: 7 ns or shorter | Noise level: 2.5 mA rms max. (bandwidth limited to 20 MHz) | Continuous allowable input: 30 A rms (requires derating at frequency) | Max. a...
Nagano, JapónCLAMP ON PROBE 3276
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 100 MHz (-3 dB) | Rise time: 3.5 ns or shorter | Noise level: 2.5 mA rms max. (bandwidth limited to 20 MHz) | Continuous allowable input: 30 A rms (requires derating at frequency) | Max...
Nagano, JapónCLAMP ON PROBE 3275
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 2 MHz (-3 dB) | Rise time: 175 ns or shorter | Noise level: 25 mA rms max. (bandwidth limited to 20 MHz) | Continuous allowable input: 500 A rms (requires derating at frequency) | Max. ...
Nagano, JapónCURRENT PROBE CT6700
Frequency bandwidth: DC to 50 MHz (-3 dB) | Rise time: 7.0 ns or shorter | Noise level: 60 μA rms typical, 75 μA rms max (for 30 MHz band measuring instrument) | Continuous allowable input: 5 A rms (DC, and sine ...
Nagano, JapónPOWER QUALITY ANALYZER PQ3198
Measurement line type: Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement) | Voltage rang...
Nagano, JapónCURRENT PROBE CT6701
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 120 MHz (-3 dB) | Rise time: 2.9 ns or shorter | Noise level: 60 μA rms typical, 75 μA rms max (for 30 MHz band measuring instrument) | Continuous allowable input: 5 A rms (DC, and sine...
Nagano, JapónSAFETY TEST DATA MANAGEMENT SOFTWARE 9267
Compatible models: ST5520*, ST5540/ST5541, 3153, 3154, 3156, 3157, 3158, 3159, 3174, 3332, 3333, 3334, and PLCs from various manufacturers (for connection switching) *Control of the ST5520 is subject to certain l...
Nagano, JapónLEAK CURRENT HiTESTER ST5541
Measurement methods: Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground. ...
Nagano, JapónSUPER MEGOHM METER SM7120
Number of channels: 1 ch | Dc current measurement: 20 pA range (0.1 fA resolution), Accuracy: ±(2.0 % of rdg. +30 dgt.) 200 pA range (1.0 fA resolution), Accuracy: ±(1.0 % of rdg. +30 dgt.) 2 nA range (10 fA re...
Nagano, JapónPLATE SAMPLE ELECTRODE SME-8310
Dimensiones: 215 mm (8,46 pulgadas) de ancho × 78 mm (3,07 pulgadas) de alto × 165 mm (6,50 pulgadas) de profundidad | Longitud de la punta: 75 cm (2.46 ft)
Nagano, Japón